Device for Measuring Creep at Higher Temperatures
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28140%2F13%3A43869961" target="_blank" >RIV/70883521:28140/13:43869961 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/70883521:28110/13:43869961
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Device for Measuring Creep at Higher Temperatures
Popis výsledku v původním jazyce
Any research and development department has ever met with the need to use a measuring device that they do not have at the time. One of the traditional methods is that such equipment is purchased from specialized companies that make them. In these cases,the question is always whether the funds spent have a large enough return and that the parameters of this machine are sufficient for the measurement. The second option which this article deals with is to design and implement such a device. One area wherethis option is possible to study is the creep behavior of radiation cross-linked polymeric material at higher temperatures. The influence of radiation crosslinking is studied in many standard short-term tests, but the influence of radiation crosslinkingon polymer materials exposed to creep is known only marginally .
Název v anglickém jazyce
Device for Measuring Creep at Higher Temperatures
Popis výsledku anglicky
Any research and development department has ever met with the need to use a measuring device that they do not have at the time. One of the traditional methods is that such equipment is purchased from specialized companies that make them. In these cases,the question is always whether the funds spent have a large enough return and that the parameters of this machine are sufficient for the measurement. The second option which this article deals with is to design and implement such a device. One area wherethis option is possible to study is the creep behavior of radiation cross-linked polymeric material at higher temperatures. The influence of radiation crosslinking is studied in many standard short-term tests, but the influence of radiation crosslinkingon polymer materials exposed to creep is known only marginally .
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JQ - Strojní zařízení a nástroje
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0089" target="_blank" >ED2.1.00/03.0089: Centrum bezpečnostních, informačních a pokročilých technologií (CEBIA-Tech)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Recent, Advances in Automatic Control, Information and Communications 14th International Conference on Automation and Information (ICAI´13) 13th International Conference on Applied Informatics and Communications (AIC´13)
ISBN
978-960-474-316-2
ISSN
1790-5117
e-ISSN
—
Počet stran výsledku
4
Strana od-do
159-162
Název nakladatele
WSEAS World Science and Engineering Academy and Science
Místo vydání
Atény
Místo konání akce
Valencie
Datum konání akce
6. 8. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—