Temperature stability of modified TPE-E by radiation cross-linking
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28140%2F13%3A43870392" target="_blank" >RIV/70883521:28140/13:43870392 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/70883521:28110/13:43870392
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Temperature stability of modified TPE-E by radiation cross-linking
Popis výsledku v původním jazyce
Radiation processing involves the use of natural or manmade sources of high energy radiation on an industrial scale. The principle of radiation processing is the ability of high energy radiation to produce reactive cations, anions and free radicals in materials. The industrial applications of the radiation processing of plastics and composites include polymerization, cross-linking, degradation and grafting. Radiation processing mainly involves the use of either electron beams from electron acceleratorsor gamma radiation from Cobalt-60 sources. The thermo-plastic elastomer (TPE-E) tested showed significant changes of temperature stability and mechanical properties after irradiation. From this point-of-view, new application could also be seen in areas with service temperatures higher than their former melting point. The comparison of hte temperature stability and mechanical properties of irradiated and non irradiated TPE-E is presented in this paper.
Název v anglickém jazyce
Temperature stability of modified TPE-E by radiation cross-linking
Popis výsledku anglicky
Radiation processing involves the use of natural or manmade sources of high energy radiation on an industrial scale. The principle of radiation processing is the ability of high energy radiation to produce reactive cations, anions and free radicals in materials. The industrial applications of the radiation processing of plastics and composites include polymerization, cross-linking, degradation and grafting. Radiation processing mainly involves the use of either electron beams from electron acceleratorsor gamma radiation from Cobalt-60 sources. The thermo-plastic elastomer (TPE-E) tested showed significant changes of temperature stability and mechanical properties after irradiation. From this point-of-view, new application could also be seen in areas with service temperatures higher than their former melting point. The comparison of hte temperature stability and mechanical properties of irradiated and non irradiated TPE-E is presented in this paper.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JP - Průmyslové procesy a zpracování
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0089" target="_blank" >ED2.1.00/03.0089: Centrum bezpečnostních, informačních a pokročilých technologií (CEBIA-Tech)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Chemické listy
ISBN
—
ISSN
0009-2770
e-ISSN
—
Počet stran výsledku
3
Strana od-do
152-154
Název nakladatele
Česká společnost chemická
Místo vydání
Praha
Místo konání akce
Bratislava
Datum konání akce
23. 4. 2013
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—