Distinguishing of different kinds of gunpowder using various methods based on terahertz radiation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28140%2F14%3A43872079" target="_blank" >RIV/70883521:28140/14:43872079 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1117/12.2067250" target="_blank" >http://dx.doi.org/10.1117/12.2067250</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1117/12.2067250" target="_blank" >10.1117/12.2067250</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Distinguishing of different kinds of gunpowder using various methods based on terahertz radiation
Popis výsledku v původním jazyce
This article provides information about using terahertz radiation based methods such as time-domain spectroscopy, ATR spectroscopy and terahertz reflection imaging for distinguishing of different kinds of gunpowder. The findings in this article prove that gunpowder does not have any sharp peaks in terahertz region of electromagnetic spectrum up to 2.5 THz, but also prove that distinguishing of different kinds of gunpowder is possible using different methods based on terahertz radiation. All presented results are connected to absorbance of gunpowder and other measured materials, because comparison of absorbance analysis is essential for distinguishing of gunpowder samples.
Název v anglickém jazyce
Distinguishing of different kinds of gunpowder using various methods based on terahertz radiation
Popis výsledku anglicky
This article provides information about using terahertz radiation based methods such as time-domain spectroscopy, ATR spectroscopy and terahertz reflection imaging for distinguishing of different kinds of gunpowder. The findings in this article prove that gunpowder does not have any sharp peaks in terahertz region of electromagnetic spectrum up to 2.5 THz, but also prove that distinguishing of different kinds of gunpowder is possible using different methods based on terahertz radiation. All presented results are connected to absorbance of gunpowder and other measured materials, because comparison of absorbance analysis is essential for distinguishing of gunpowder samples.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Millimetre Wave and Terahertz Sensors and Technology VII
ISBN
978-1-62841-315-1
ISSN
0277-786X
e-ISSN
—
Počet stran výsledku
9
Strana od-do
"Neuvedeno"
Název nakladatele
SPIE - International Society for Optical Engineering
Místo vydání
Bellingham
Místo konání akce
Amsterdam
Datum konání akce
24. 9. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000345030100007