Difficulties of heat transfer from PCM type board to ambient room
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28140%2F15%3A43873217" target="_blank" >RIV/70883521:28140/15:43873217 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Difficulties of heat transfer from PCM type board to ambient room
Popis výsledku v původním jazyce
In this article authors present results of the research performed on the thermal storage panel based on the phase change material (PCM) in conventional climatic conditions for the interior of the building. The research was performed on accumulation panels, which are installed in the laboratory of Integrated systems in buildings on Faculty of Applied Informatics, Tomas Bata University in Zlin. Heat foils were used as heating source for accumulation panels. These foils use energy produced by photovoltaicpanels and provide low cost source for heating, other option for heating is water pipe exchanger that is installed inside the panels. Water pipe exchanger can provide cooling of panels, which use cooled water by Peltier elements or heat pump. Purpose ofthe research was to make measurement of thermal behavior while panel is cooled or heated in order to obtain important accumulation parameters and heat transfer parameters from the surface of the panel. Use of the panel is tied with regula
Název v anglickém jazyce
Difficulties of heat transfer from PCM type board to ambient room
Popis výsledku anglicky
In this article authors present results of the research performed on the thermal storage panel based on the phase change material (PCM) in conventional climatic conditions for the interior of the building. The research was performed on accumulation panels, which are installed in the laboratory of Integrated systems in buildings on Faculty of Applied Informatics, Tomas Bata University in Zlin. Heat foils were used as heating source for accumulation panels. These foils use energy produced by photovoltaicpanels and provide low cost source for heating, other option for heating is water pipe exchanger that is installed inside the panels. Water pipe exchanger can provide cooling of panels, which use cooled water by Peltier elements or heat pump. Purpose ofthe research was to make measurement of thermal behavior while panel is cooled or heated in order to obtain important accumulation parameters and heat transfer parameters from the surface of the panel. Use of the panel is tied with regula
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0089" target="_blank" >ED2.1.00/03.0089: Centrum bezpečnostních, informačních a pokročilých technologií (CEBIA-Tech)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Advanced building skins
ISBN
9783981205381
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
667-672
Název nakladatele
Economic Forum
Místo vydání
Munich
Místo konání akce
Bern
Datum konání akce
3. 11. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—