Experimental and Numerical Testing of Possibilities and Limits for Applications of Phase Changed Materials in Buildings
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28140%2F19%3A63522716" target="_blank" >RIV/70883521:28140/19:63522716 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.matec-conferences.org/articles/matecconf/pdf/2019/41/matecconf_cscc2019_01022.pdf" target="_blank" >https://www.matec-conferences.org/articles/matecconf/pdf/2019/41/matecconf_cscc2019_01022.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/matecconf/201929201022" target="_blank" >10.1051/matecconf/201929201022</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Experimental and Numerical Testing of Possibilities and Limits for Applications of Phase Changed Materials in Buildings
Popis výsledku v původním jazyce
The paper is aimed atto a study of a possibility to use PCM (Phase Change Materials) to increase the thermal storage properties of buildings. For this purpose, both the experimental testing and computer modelling were performed. The PCM DuPont Energain panel was used for the study of its thermal technical parameters under laboratory conditions. Laboratory testing of the effect of PCM surface treatment showed a double increase in the heat transfer coefficient, but also a decrease of 17 % in the time constant under given conditions. The computer modelling was used for the study of the influence of walls sheathing on the temperature comfort inside the tested room of the wooden house by its passive cooling in summer. Results of the numerical simulations proved influence of the PCM covering. But in the presented model, the PCM covering caused only a slight improvement in the thermal comfort inside the room.
Název v anglickém jazyce
Experimental and Numerical Testing of Possibilities and Limits for Applications of Phase Changed Materials in Buildings
Popis výsledku anglicky
The paper is aimed atto a study of a possibility to use PCM (Phase Change Materials) to increase the thermal storage properties of buildings. For this purpose, both the experimental testing and computer modelling were performed. The PCM DuPont Energain panel was used for the study of its thermal technical parameters under laboratory conditions. Laboratory testing of the effect of PCM surface treatment showed a double increase in the heat transfer coefficient, but also a decrease of 17 % in the time constant under given conditions. The computer modelling was used for the study of the influence of walls sheathing on the temperature comfort inside the tested room of the wooden house by its passive cooling in summer. Results of the numerical simulations proved influence of the PCM covering. But in the presented model, the PCM covering caused only a slight improvement in the thermal comfort inside the room.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1303" target="_blank" >LO1303: Podpora udržitelnosti a rozvoje Centra bezpečnostních, informačních a pokročilých technologií (CEBIA-Tech)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
MATEC Web of Conferences 292
ISBN
—
ISSN
2261-236X
e-ISSN
2261-236X
Počet stran výsledku
6
Strana od-do
1-6
Název nakladatele
EDP Sciences
Místo vydání
Les Ulis
Místo konání akce
Athens
Datum konání akce
14. 7. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—