A modeling study on the reverse cycle defrosting of an air source heat pump with the melted frost downwards flowing away and local drainage
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28140%2F20%3A63525216" target="_blank" >RIV/70883521:28140/20:63525216 - isvavai.cz</a>
Výsledek na webu
<a href="https://reader.elsevier.com/reader/sd/pii/S0378778820306605?token=4FDC40FB4D647F31E3AA897B21E06BAE179D2FF86C14AFB63356756EFE57A98AD50F7B663C55DC1C791BD3C2D2BD9977" target="_blank" >https://reader.elsevier.com/reader/sd/pii/S0378778820306605?token=4FDC40FB4D647F31E3AA897B21E06BAE179D2FF86C14AFB63356756EFE57A98AD50F7B663C55DC1C791BD3C2D2BD9977</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.enbuild.2020.110257" target="_blank" >10.1016/j.enbuild.2020.110257</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A modeling study on the reverse cycle defrosting of an air source heat pump with the melted frost downwards flowing away and local drainage
Popis výsledku v původním jazyce
Reverse cycle defrosting is widely used for air source heat pumps. When a multi-circuit heat exchanger is vertically installed in a heat pump as an outdoor coil, the melted frost could be kept downwards flowing or locally drained during defrosting by using water collecting trays. To analyze the performance differences of melted frost, two defrosting models were developed and previously reported by authors. In this study, the defrosting performance of an air source heat pump was numerically investigated based on the two models, with the melted frost downwards flowing away or local drainage considered. The following physical parameters are predicted and analyzed, including the thermal resistance of refrigerant, temperature of melted frost on tube and fin's surface, mass of melted frost and energy consumption from refrigerant during defrosting. As calculated, after the melted frost locally drained, the predicted total energy consumption could be decreased from 898.1 kJ to 727.5 kJ, and defrosting efficiency increased from 47.5% to 57.6%. This work is helpful to optimizing the intelligent control strategy of an air source heat pump unit, as well as saving energy for buildings
Název v anglickém jazyce
A modeling study on the reverse cycle defrosting of an air source heat pump with the melted frost downwards flowing away and local drainage
Popis výsledku anglicky
Reverse cycle defrosting is widely used for air source heat pumps. When a multi-circuit heat exchanger is vertically installed in a heat pump as an outdoor coil, the melted frost could be kept downwards flowing or locally drained during defrosting by using water collecting trays. To analyze the performance differences of melted frost, two defrosting models were developed and previously reported by authors. In this study, the defrosting performance of an air source heat pump was numerically investigated based on the two models, with the melted frost downwards flowing away or local drainage considered. The following physical parameters are predicted and analyzed, including the thermal resistance of refrigerant, temperature of melted frost on tube and fin's surface, mass of melted frost and energy consumption from refrigerant during defrosting. As calculated, after the melted frost locally drained, the predicted total energy consumption could be decreased from 898.1 kJ to 727.5 kJ, and defrosting efficiency increased from 47.5% to 57.6%. This work is helpful to optimizing the intelligent control strategy of an air source heat pump unit, as well as saving energy for buildings
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20303 - Thermodynamics
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F19.0376" target="_blank" >ED2.1.00/19.0376: CEBIA - Tech Instrumentation</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Energy and Buildings
ISSN
0378-7788
e-ISSN
—
Svazek periodika
226
Číslo periodika v rámci svazku
neuveden
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
14
Strana od-do
1-14
Kód UT WoS článku
000573584200003
EID výsledku v databázi Scopus
2-s2.0-85089075807