Effect of temperature ageing on injection molded high-density polyethylene parts modified by accelerated electrons
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28140%2F22%3A63554578" target="_blank" >RIV/70883521:28140/22:63554578 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.mdpi.com/1996-1944/15/3/742" target="_blank" >https://www.mdpi.com/1996-1944/15/3/742</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/ma15030742" target="_blank" >10.3390/ma15030742</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of temperature ageing on injection molded high-density polyethylene parts modified by accelerated electrons
Popis výsledku v původním jazyce
The temperature ageing of high-density polyethylene (HDPE) modified by accelerated electrons was studied. Commodity plastic HDPE was used as a basic polymer material which was modified by radiation cross-linking. This polymer was used because of its excellent processability and chemical resistance. Plastic injection molding technology was used for the production of test specimens. These specimens were modified with the dose of radiation 33, 66, 99, 132, 165, and 198 kGy. The prepared specimens were tested to determine: gel content, degree of swelling, temperature stability, and changes in mechanical properties after temperature ageing. The results were determined by scanning electron microscopy (SEM) analysis on the fracture surfaces. The results of this study confirm that modification of HDPE by radiation cross-linking has a significant effect on increasing temperature stability. It has been shown that HDPE modified by radiation cross-linking can withstand temperatures exceeding the melting point of the original HDPE for a short-term.
Název v anglickém jazyce
Effect of temperature ageing on injection molded high-density polyethylene parts modified by accelerated electrons
Popis výsledku anglicky
The temperature ageing of high-density polyethylene (HDPE) modified by accelerated electrons was studied. Commodity plastic HDPE was used as a basic polymer material which was modified by radiation cross-linking. This polymer was used because of its excellent processability and chemical resistance. Plastic injection molding technology was used for the production of test specimens. These specimens were modified with the dose of radiation 33, 66, 99, 132, 165, and 198 kGy. The prepared specimens were tested to determine: gel content, degree of swelling, temperature stability, and changes in mechanical properties after temperature ageing. The results were determined by scanning electron microscopy (SEM) analysis on the fracture surfaces. The results of this study confirm that modification of HDPE by radiation cross-linking has a significant effect on increasing temperature stability. It has been shown that HDPE modified by radiation cross-linking can withstand temperatures exceeding the melting point of the original HDPE for a short-term.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Materials
ISSN
1996-1944
e-ISSN
—
Svazek periodika
15
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
19
Strana od-do
nestrankovano
Kód UT WoS článku
000754585000001
EID výsledku v databázi Scopus
2-s2.0-85123199792