Influence of temperature and transmitted power on losses in particular transmission system
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28140%2F22%3A63556239" target="_blank" >RIV/70883521:28140/22:63556239 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61988987:17450/22:A2302FHW
Výsledek na webu
<a href="https://wseas.com/journals/ps/2022/a125116-005(2022).pdf" target="_blank" >https://wseas.com/journals/ps/2022/a125116-005(2022).pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.37394/232016.2022.17.6" target="_blank" >10.37394/232016.2022.17.6</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of temperature and transmitted power on losses in particular transmission system
Popis výsledku v původním jazyce
Innovations and trends has been significantly increased during modern theory and practical realizations in the field of energetic. In the Czech Republic, the research of predictions of technical losses on the transmission system can be considered as novel and important topic. Using software possibilities can be appropriately utilized in the frame of estimations of the technical losses. While they cannot be eliminated, they may be minimized. Losses can be measured or calculated using transmission-line parameters. This causality is considered in the form of the presented and proposed mathematical equations including real measured data of the atmospheric temperatures achieved on the substations selected in the Moravian-Silesian region. In this contribution, results of proposed calculations of technical losses based only on line parameters considering the ambient temperature are being compared in relation to a particular transmission system using prediction software. Particularly, technical losses caused by a configuration change of a selected part of a transmission system are considered related to the operation of Dlouhe Strane pumped storage hydro power plant. As can be conclude, after the resulted comparisons using by the proposed mathematical models in software and the obtained real measured data, general minimization of the losses is necessary to create the most accurate models of the states that might occur in the future and to propose required modifications of the given part of the transmission system. Future bounded research can be focused on the sensors situated on the transmission lines instead of the substations.
Název v anglickém jazyce
Influence of temperature and transmitted power on losses in particular transmission system
Popis výsledku anglicky
Innovations and trends has been significantly increased during modern theory and practical realizations in the field of energetic. In the Czech Republic, the research of predictions of technical losses on the transmission system can be considered as novel and important topic. Using software possibilities can be appropriately utilized in the frame of estimations of the technical losses. While they cannot be eliminated, they may be minimized. Losses can be measured or calculated using transmission-line parameters. This causality is considered in the form of the presented and proposed mathematical equations including real measured data of the atmospheric temperatures achieved on the substations selected in the Moravian-Silesian region. In this contribution, results of proposed calculations of technical losses based only on line parameters considering the ambient temperature are being compared in relation to a particular transmission system using prediction software. Particularly, technical losses caused by a configuration change of a selected part of a transmission system are considered related to the operation of Dlouhe Strane pumped storage hydro power plant. As can be conclude, after the resulted comparisons using by the proposed mathematical models in software and the obtained real measured data, general minimization of the losses is necessary to create the most accurate models of the states that might occur in the future and to propose required modifications of the given part of the transmission system. Future bounded research can be focused on the sensors situated on the transmission lines instead of the substations.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20205 - Automation and control systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
WSEAS Transactions on Power Systems
ISSN
1790-5060
e-ISSN
—
Svazek periodika
17
Číslo periodika v rámci svazku
Neuveden
Stát vydavatele periodika
GR - Řecká republika
Počet stran výsledku
9
Strana od-do
53-61
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85129793213