Analysis of Antibacterial Action of Polyvinyl Chloride Surface Modified with Gentian Violet
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28610%2F09%3A63508769" target="_blank" >RIV/70883521:28610/09:63508769 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of Antibacterial Action of Polyvinyl Chloride Surface Modified with Gentian Violet
Popis výsledku v původním jazyce
The effect of incorporation of gentian violet into medical-grade polyvinyl chloride was studied in this work. The antibacterial properties of the resulting blend were evaluated and the influence of the amount of gentian violet assessed. Dispersion of thegentian violet int the polyvinyl chloride following the blending of the two components was uniform as was demonstrated by the optical images, which is important for any further analysis. The samples of the blend were modified compared to the PVC samplesthat were not treated with gentian violet. This was clearly demonstrated by the scanning electron microscope images. Water contact angles reduced from 77.2 degrees for the pure sample to lower values for the modified samples, signaling that the hydrophilicity of the modified samples was improved. All of these results correlated well with the antimicrobial investigations, which showed inhibition of Staphylococcus aureus action by the modified samples, but no inhibition by the pure sample
Název v anglickém jazyce
Analysis of Antibacterial Action of Polyvinyl Chloride Surface Modified with Gentian Violet
Popis výsledku anglicky
The effect of incorporation of gentian violet into medical-grade polyvinyl chloride was studied in this work. The antibacterial properties of the resulting blend were evaluated and the influence of the amount of gentian violet assessed. Dispersion of thegentian violet int the polyvinyl chloride following the blending of the two components was uniform as was demonstrated by the optical images, which is important for any further analysis. The samples of the blend were modified compared to the PVC samplesthat were not treated with gentian violet. This was clearly demonstrated by the scanning electron microscope images. Water contact angles reduced from 77.2 degrees for the pure sample to lower values for the modified samples, signaling that the hydrophilicity of the modified samples was improved. All of these results correlated well with the antimicrobial investigations, which showed inhibition of Staphylococcus aureus action by the modified samples, but no inhibition by the pure sample
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CD - Makromolekulární chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/2A-1TP1%2F126" target="_blank" >2A-1TP1/126: Inovace zdravotnických pomůcek na polymerní bázi (Fakulta technologická ve Zlíně).</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Polymer Analysis and Characterization
ISSN
1023-666X
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—