Enhanced magnetorheological effect of suspensions based on carbonyl iron particles coated with poly(amidoamine) dendrons
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28610%2F21%3A63529078" target="_blank" >RIV/70883521:28610/21:63529078 - isvavai.cz</a>
Výsledek na webu
<a href="https://link.springer.com/article/10.1007/s00397-021-01269-1" target="_blank" >https://link.springer.com/article/10.1007/s00397-021-01269-1</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00397-021-01269-1" target="_blank" >10.1007/s00397-021-01269-1</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Enhanced magnetorheological effect of suspensions based on carbonyl iron particles coated with poly(amidoamine) dendrons
Popis výsledku v původním jazyce
Particle oxidation constitutes a serious ageing phenomenon in magnetorheological suspensions, bringing about deterioration in performance. This study describes commercial carbonyl iron particles that were successfully coated with poly(amidoamine) dendrons and then applied as an oxidation-resistant dispersed phase in magnetorheological suspensions. A synthesis method was adhered to whereby the particles were sequentially treated with ethylenediamine and methyl acrylate, leading to the formation of generation 2 and 2.5 dendrons; these had the capacity for composite particles with a nano-scale dendritic layer to be prepared on their surfaces. Success in applying the coating was confirmed by various techniques, including XPS, TEM, EDX, FTIR and Raman spectroscopy. The controlled approach adopted to coating the carbonyl iron particles resulted in them exhibiting sufficient oxidation stability, with only an ~ 4.5–4.7% decrease in saturation magnetization. Of interest was that their magnetorheological suspensions demonstrated ca 4.8% and 4% higher dynamic yield stress than a suspension based on non-modified particles at the highest intensity of magnetic field investigated, i.e. 438 kA m–1. Notably, sedimentation stability was evaluated by a unique method that involved the use of a tensiometer with a specific testing probe. The aforementioned coating process led to enhanced sedimentation stability of the magnetorheological suspensions based on coated particles possibly due to decrease in the overall density of the particles, enhanced dispersion stability and reduction in the size of their agglomerates in the silicone oil mixtures that were confirmed by optical microscopy. Modification of the particles as proposed has the potential to overcome one of the primary drawbacks of magnetorheological suspensions, this being oxidation instability (which leads to what is referred to as “in-use-thickening”), without negatively affecting their performance in the presence of a magnetic field.
Název v anglickém jazyce
Enhanced magnetorheological effect of suspensions based on carbonyl iron particles coated with poly(amidoamine) dendrons
Popis výsledku anglicky
Particle oxidation constitutes a serious ageing phenomenon in magnetorheological suspensions, bringing about deterioration in performance. This study describes commercial carbonyl iron particles that were successfully coated with poly(amidoamine) dendrons and then applied as an oxidation-resistant dispersed phase in magnetorheological suspensions. A synthesis method was adhered to whereby the particles were sequentially treated with ethylenediamine and methyl acrylate, leading to the formation of generation 2 and 2.5 dendrons; these had the capacity for composite particles with a nano-scale dendritic layer to be prepared on their surfaces. Success in applying the coating was confirmed by various techniques, including XPS, TEM, EDX, FTIR and Raman spectroscopy. The controlled approach adopted to coating the carbonyl iron particles resulted in them exhibiting sufficient oxidation stability, with only an ~ 4.5–4.7% decrease in saturation magnetization. Of interest was that their magnetorheological suspensions demonstrated ca 4.8% and 4% higher dynamic yield stress than a suspension based on non-modified particles at the highest intensity of magnetic field investigated, i.e. 438 kA m–1. Notably, sedimentation stability was evaluated by a unique method that involved the use of a tensiometer with a specific testing probe. The aforementioned coating process led to enhanced sedimentation stability of the magnetorheological suspensions based on coated particles possibly due to decrease in the overall density of the particles, enhanced dispersion stability and reduction in the size of their agglomerates in the silicone oil mixtures that were confirmed by optical microscopy. Modification of the particles as proposed has the potential to overcome one of the primary drawbacks of magnetorheological suspensions, this being oxidation instability (which leads to what is referred to as “in-use-thickening”), without negatively affecting their performance in the presence of a magnetic field.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20301 - Mechanical engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F19.0409" target="_blank" >ED2.1.00/19.0409: CPS - posílení výzkumných kapacit</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Rheologica Acta
ISSN
0035-4511
e-ISSN
—
Svazek periodika
60
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
14
Strana od-do
263-276
Kód UT WoS článku
000636914000001
EID výsledku v databázi Scopus
2-s2.0-85103646714