Development of a negative pressure based active lung simulator
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F71226401%3A_____%2F12%3A%230000131" target="_blank" >RIV/71226401:_____/12:#0000131 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Development of a negative pressure based active lung simulator
Popis výsledku v původním jazyce
Nowadays lung simulators are an important part of respirator testing, diagnostics, therapy, education and training. Those simulators are developed to simulate human lungs and respiration processes. In the case of an active lung simulator the focus is puton the simulation for physiological and pathological breathing patterns. The presented i-Lung versions are hybrids of active and passive lung simulators. They have a thoracic chamber in common, which is made of PMMA (Polymethylmethacrylate) and in whichdifferent lung equivalents can be mounted. The expansion of the lung equivalent is performed by application of negative pressure which is controlled via an adjacent controlling unit. Over the course of time the i-lung model-starting with version 0.1, 1.0 and finally the oncoming model 2.0-was mainly changed in the setup of the breathing pattern generation. The changes of the setup led to a module based setup of the entire model leading to high flexibility of fields of application and fa
Název v anglickém jazyce
Development of a negative pressure based active lung simulator
Popis výsledku anglicky
Nowadays lung simulators are an important part of respirator testing, diagnostics, therapy, education and training. Those simulators are developed to simulate human lungs and respiration processes. In the case of an active lung simulator the focus is puton the simulation for physiological and pathological breathing patterns. The presented i-Lung versions are hybrids of active and passive lung simulators. They have a thoracic chamber in common, which is made of PMMA (Polymethylmethacrylate) and in whichdifferent lung equivalents can be mounted. The expansion of the lung equivalent is performed by application of negative pressure which is controlled via an adjacent controlling unit. Over the course of time the i-lung model-starting with version 0.1, 1.0 and finally the oncoming model 2.0-was mainly changed in the setup of the breathing pattern generation. The changes of the setup led to a module based setup of the entire model leading to high flexibility of fields of application and fa
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20204 - Robotics and automatic control
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of 15th International Conference on Mechatronics ? Mechatronika 2012
ISBN
978-80-01-04985-3
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
318-323
Název nakladatele
České vysoké učení technické v Praze
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
5. 12. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000324949300060