Impact of indoor surface material on perceived air quality
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F75081431%3A_____%2F14%3A00000413" target="_blank" >RIV/75081431:_____/14:00000413 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.msec.2013.11.032" target="_blank" >http://dx.doi.org/10.1016/j.msec.2013.11.032</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.msec.2013.11.032" target="_blank" >10.1016/j.msec.2013.11.032</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Impact of indoor surface material on perceived air quality
Popis výsledku v původním jazyce
The material combination impact on perceived indoor air quality for various surface interior materials is presented in this paper. The chemical analysis and sensory assessments identifies health adverse of indoor air pollutants (TVOCs). In this study, emissions and odors from different common indoor surface materials were investigated in glass test chamber under standardized conditions. Chemical measurements (TVOC concentration) and sensory assessments (odor intensity, air acceptability) were done afterbuilding materials exposure to standardized conditions. The results of the chemical and sensory assessment of individual materials and their combinations are compared and discussed within the paper. The using possibility of individual material surface sorption ability was investigated. The knowledge of targeted sorption effects can be used in the interior design phase.
Název v anglickém jazyce
Impact of indoor surface material on perceived air quality
Popis výsledku anglicky
The material combination impact on perceived indoor air quality for various surface interior materials is presented in this paper. The chemical analysis and sensory assessments identifies health adverse of indoor air pollutants (TVOCs). In this study, emissions and odors from different common indoor surface materials were investigated in glass test chamber under standardized conditions. Chemical measurements (TVOC concentration) and sensory assessments (odor intensity, air acceptability) were done afterbuilding materials exposure to standardized conditions. The results of the chemical and sensory assessment of individual materials and their combinations are compared and discussed within the paper. The using possibility of individual material surface sorption ability was investigated. The knowledge of targeted sorption effects can be used in the interior design phase.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS
ISSN
0928-4931
e-ISSN
—
Svazek periodika
Neuveden
Číslo periodika v rámci svazku
36
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
1-6
Kód UT WoS článku
000331509300001
EID výsledku v databázi Scopus
—