Problems of airflow in the open air space between double skin roofs of passive objects
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F75081431%3A_____%2F17%3A00001132" target="_blank" >RIV/75081431:_____/17:00001132 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Problems of airflow in the open air space between double skin roofs of passive objects
Popis výsledku v původním jazyce
This contribution deals with the verification of airflow in the real air gap of an insulated roof deck with a pitched roof. The designed construction of the roof meets the thermal technical requirements for an energy passive house. The aim of this contribution is a comparison of experimentally measured values with values obtained through a computer simulation. Double skin ventilated roof structures operate on the principle of the removal of moisture vapour by the flow of air. The flow of air is generated by the difference in the density of the air gap. The air gap is created by the warming of the air from the interior, radiation from the night sky and the influence of the external flow of air. The most striking was the first factor, which is significantly reduced with increasing thicknesses of thermal insulation. This raises the issue whether the air flow in passive insulated roof cladding is sufficient for the removal of moisture from a construction, and how it affects the functioning thereof.
Název v anglickém jazyce
Problems of airflow in the open air space between double skin roofs of passive objects
Popis výsledku anglicky
This contribution deals with the verification of airflow in the real air gap of an insulated roof deck with a pitched roof. The designed construction of the roof meets the thermal technical requirements for an energy passive house. The aim of this contribution is a comparison of experimentally measured values with values obtained through a computer simulation. Double skin ventilated roof structures operate on the principle of the removal of moisture vapour by the flow of air. The flow of air is generated by the difference in the density of the air gap. The air gap is created by the warming of the air from the interior, radiation from the night sky and the influence of the external flow of air. The most striking was the first factor, which is significantly reduced with increasing thicknesses of thermal insulation. This raises the issue whether the air flow in passive insulated roof cladding is sufficient for the removal of moisture from a construction, and how it affects the functioning thereof.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
17th International Multidisciplinary Scientific GeoConference
ISBN
9786197408133
ISSN
—
e-ISSN
—
Počet stran výsledku
13
Strana od-do
367-374
Název nakladatele
STEF92 TECHNOLOGY LTD
Místo vydání
Sofia (Bulharsko)
Místo konání akce
Albena
Datum konání akce
29. 5. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—