Popis výsledku v původním jazyce
Collar roofs belong to the traditional structures used for roofing buildings. In present, the collar roofs are widely used for their ability to omit internal vertical support structures (columns, support walls), which might be sometimes a complication during a design of the layout of the building. Collar roof acts on the bottom support structure of the building by quite big lateral horizontal forces. These forces are being often neglected in common practice. This fact leads to failures of the bottom support structures. Reinforced concrete rim made on the top of the brick wall is one of the methods, how to deal with these horizontal forces. The article deals with the interaction. The article deals with the interaction between the structure of the collar roof and the reinforced concrete rim.
Název v anglickém jazyce
Interaction of collar roof with the bottom support structure of a building
Popis výsledku anglicky
Collar roofs belong to the traditional structures used for roofing buildings. In present, the collar roofs are widely used for their ability to omit internal vertical support structures (columns, support walls), which might be sometimes a complication during a design of the layout of the building. Collar roof acts on the bottom support structure of the building by quite big lateral horizontal forces. These forces are being often neglected in common practice. This fact leads to failures of the bottom support structures. Reinforced concrete rim made on the top of the brick wall is one of the methods, how to deal with these horizontal forces. The article deals with the interaction. The article deals with the interaction between the structure of the collar roof and the reinforced concrete rim.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
9th International Scientific Conference Building Defects (Building Defects 2017)
ISBN
9782759890323
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
MATEC Web of Conferences
Místo vydání
Česká republika
Místo konání akce
České Budějovice
Datum konání akce
23. 11. 2017
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—