Interior Materials Combination and Perceived Indoor Air Quality
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F75081431%3A_____%2F19%3A00001847" target="_blank" >RIV/75081431:_____/19:00001847 - isvavai.cz</a>
Výsledek na webu
<a href="https://apps.webofknowledge.com/full_record.do?product=WOS&search_mode=GeneralSearch&qid=9&SID=F6pPNRHSgTorSACe4fL&page=1&doc=1" target="_blank" >https://apps.webofknowledge.com/full_record.do?product=WOS&search_mode=GeneralSearch&qid=9&SID=F6pPNRHSgTorSACe4fL&page=1&doc=1</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Interior Materials Combination and Perceived Indoor Air Quality
Popis výsledku v původním jazyce
The materials used in the buildings, either as surface structural materials or as furnishings, are mostly the sources of indoor air pollution. Interior surfaces are generally accepted as the main source of indoor TVOCs emissions. The poor indoor microclimate quality can cause the sick building syndrome, as well as negatively affects the people activities and wellbeing. In recent years the needs of indoor air quality and building performance improvement have been increasing. The indoor materials impact on perceived indoor air quality for various surface interior materials and its combination was studied within this paper. Traditional and progressive materials comparison reveals new fact regarding the TVOCs concentration. The task of the study was to investigate the possibility using individual material surfaces sorption ability. The chemical analysis and sensory assessments identifies health adverse of indoor air pollutants (TVOCs). Also we can use knowledge about the targeted use of sorption effect already in the building design phase. The results demonstrate the various sorption abilities of various indoor materials as well as various sorption ability of the same indoor material in various combinations.
Název v anglickém jazyce
Interior Materials Combination and Perceived Indoor Air Quality
Popis výsledku anglicky
The materials used in the buildings, either as surface structural materials or as furnishings, are mostly the sources of indoor air pollution. Interior surfaces are generally accepted as the main source of indoor TVOCs emissions. The poor indoor microclimate quality can cause the sick building syndrome, as well as negatively affects the people activities and wellbeing. In recent years the needs of indoor air quality and building performance improvement have been increasing. The indoor materials impact on perceived indoor air quality for various surface interior materials and its combination was studied within this paper. Traditional and progressive materials comparison reveals new fact regarding the TVOCs concentration. The task of the study was to investigate the possibility using individual material surfaces sorption ability. The chemical analysis and sensory assessments identifies health adverse of indoor air pollutants (TVOCs). Also we can use knowledge about the targeted use of sorption effect already in the building design phase. The results demonstrate the various sorption abilities of various indoor materials as well as various sorption ability of the same indoor material in various combinations.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20100 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
MATEC Web of Conferences, 279 (2019): 10th International Scientific Conference Building Defects (Building Defects 2018)
ISBN
—
ISSN
2261-236X
e-ISSN
—
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
EDP Sciences
Místo vydání
Francie
Místo konání akce
30 11 2018
Datum konání akce
29. 11. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku