Diagnostics of Flat Roofs with Flexible Sheets for Waterproofing
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F75081431%3A_____%2F20%3A00001717" target="_blank" >RIV/75081431:_____/20:00001717 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1088/1757-899X/728/1/012004" target="_blank" >http://dx.doi.org/10.1088/1757-899X/728/1/012004</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1757-899X/728/1/012004" target="_blank" >10.1088/1757-899X/728/1/012004</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Diagnostics of Flat Roofs with Flexible Sheets for Waterproofing
Popis výsledku v původním jazyce
This paper deals with diagnostics of flat roofs with flexible sheets for waterproofing (membrane). The diagnostics is focused on defects and water tightness of membrane. The roof is one of the building's most important building envelope. In case of defect, the other layers of the roof, including the structure frame, are degraded. The introduction gives an overview of individual methods and their division. The following part describes advantages and drawbacks of the individual methods. The next part is focused on the following type of test - High Voltage Membrane Testing. The test is described in detail, including the Conductive detection membrane, which was developed specifically for this method. This test, in combination with other methods, seems optimal, but it is most reliable to prevent possible defects by following technological procedures.
Název v anglickém jazyce
Diagnostics of Flat Roofs with Flexible Sheets for Waterproofing
Popis výsledku anglicky
This paper deals with diagnostics of flat roofs with flexible sheets for waterproofing (membrane). The diagnostics is focused on defects and water tightness of membrane. The roof is one of the building's most important building envelope. In case of defect, the other layers of the roof, including the structure frame, are degraded. The introduction gives an overview of individual methods and their division. The following part describes advantages and drawbacks of the individual methods. The next part is focused on the following type of test - High Voltage Membrane Testing. The test is described in detail, including the Conductive detection membrane, which was developed specifically for this method. This test, in combination with other methods, seems optimal, but it is most reliable to prevent possible defects by following technological procedures.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IOP Conference Series: Materials Science and Engineering, volume 728, issue 1 (11th International Conference Building Defects 2019)
ISBN
—
ISSN
1757-8981
e-ISSN
—
Počet stran výsledku
7
Strana od-do
—
Název nakladatele
Institute of Physics Publishing
Místo vydání
Spojené království
Místo konání akce
České Budějovice
Datum konání akce
28. 11. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—