Perceived Air Quality and Productivity in the Office Building
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F75081431%3A_____%2F20%3A00001922" target="_blank" >RIV/75081431:_____/20:00001922 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1088/1757-899X/960/4/042088" target="_blank" >http://dx.doi.org/10.1088/1757-899X/960/4/042088</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1757-899X/960/4/042088" target="_blank" >10.1088/1757-899X/960/4/042088</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Perceived Air Quality and Productivity in the Office Building
Popis výsledku v původním jazyce
Problems of perceived quality of the environment find its reason especially when monitoring performance and productivity of work. Thus, verification of the degree of environmental quality impact on employee performance comes into consideration. The results of two independent studies involving 50 subjects, and using similar procedures and blind exposures have shown that increasing the air quality (by decreasing the pollution load or by increasing the ventilation rate, with otherwise constant indoor climate conditions) can improve the performance of simulated office work (text typing, addition and proof-reading). Performance testing was performed in the open space office of an office building at three air exchange intensities: n1 = 0.5 h-1, n2 = 1.5 h-1 and n3 = 2.5 h-1. Other physical environmental parameters that could have affected the assessors' performance were maintained in the range: indoor air temperature, relative air humidity, air velocity, noise level load L = 40 - 50 dB (A), daylight - diffuse radiation component. The present results document the productivity benefits of providing good indoor air quality and indicate that providing indoor air of a higher ventilation level will increase productivity.
Název v anglickém jazyce
Perceived Air Quality and Productivity in the Office Building
Popis výsledku anglicky
Problems of perceived quality of the environment find its reason especially when monitoring performance and productivity of work. Thus, verification of the degree of environmental quality impact on employee performance comes into consideration. The results of two independent studies involving 50 subjects, and using similar procedures and blind exposures have shown that increasing the air quality (by decreasing the pollution load or by increasing the ventilation rate, with otherwise constant indoor climate conditions) can improve the performance of simulated office work (text typing, addition and proof-reading). Performance testing was performed in the open space office of an office building at three air exchange intensities: n1 = 0.5 h-1, n2 = 1.5 h-1 and n3 = 2.5 h-1. Other physical environmental parameters that could have affected the assessors' performance were maintained in the range: indoor air temperature, relative air humidity, air velocity, noise level load L = 40 - 50 dB (A), daylight - diffuse radiation component. The present results document the productivity benefits of providing good indoor air quality and indicate that providing indoor air of a higher ventilation level will increase productivity.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IOP Conference Series : Materials Science and Engineering
ISBN
—
ISSN
1757-8981
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1-6
Název nakladatele
IOP Publishing
Místo vydání
Neuveden
Místo konání akce
Prague
Datum konání akce
1. 9. 2020
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—