Retrospective dose reconstruction using hausehold salt
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F12%3A%230000017" target="_blank" >RIV/86652052:_____/12:#0000017 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.irpa13glasgow.com/information/downloads/" target="_blank" >http://www.irpa13glasgow.com/information/downloads/</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Retrospective dose reconstruction using hausehold salt
Popis výsledku v původním jazyce
In the event of large scale radiation accidents or malevolent acts with radioactive materials, non-invasive and sufficiently accurate retrospective dosimetry methods are necessary for fast triage and quantitative dose estimate of the stricken individuals. NaCl in form of household salt is a cheap and widely available material. This study investigated the potential of household salt for purposes of retrospective and accident dosimetry using optically stimulated luminescence (OSL). Attention was concentrated on sensitivity and background signal, minimum detectable dose, dose and energy dependence of the OSL signal, fading, optimisation of the OSL read-out procedure and application of analytical protocols which do not require a specific calibration. A potential of NaCl as a neutron activation dosemeter was considered also. The behaviour of the OSL signal observed was found to be favourable for dosimetry.
Název v anglickém jazyce
Retrospective dose reconstruction using hausehold salt
Popis výsledku anglicky
In the event of large scale radiation accidents or malevolent acts with radioactive materials, non-invasive and sufficiently accurate retrospective dosimetry methods are necessary for fast triage and quantitative dose estimate of the stricken individuals. NaCl in form of household salt is a cheap and widely available material. This study investigated the potential of household salt for purposes of retrospective and accident dosimetry using optically stimulated luminescence (OSL). Attention was concentrated on sensitivity and background signal, minimum detectable dose, dose and energy dependence of the OSL signal, fading, optimisation of the OSL read-out procedure and application of analytical protocols which do not require a specific calibration. A potential of NaCl as a neutron activation dosemeter was considered also. The behaviour of the OSL signal observed was found to be favourable for dosimetry.
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
DL - Jaderné odpady, radioaktivní znečištění a kontrola
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/VF20102015014" target="_blank" >VF20102015014: Výzkum pokročilých metod detekce, stanovení a následné zvládnutí radioaktivní kontaminace</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
—
Místo vydání
Glasgow
Název nakladatele resp. objednatele
International Radiation Protection Association
Verze
—
Identifikační číslo nosiče
—