Radon entry rate analyses using in-situ tracer gas method aplication
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F13%3A%230000171" target="_blank" >RIV/86652052:_____/13:#0000171 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Radon entry rate analyses using in-situ tracer gas method aplication
Popis výsledku v původním jazyce
Recently, the role of energy savings in indoor air quality deterioration has been extensively emphasized, predominantly in the context of significant air exchange rate reduction as a result of home energy retrofits. In case of refurbishment of existing buildings, the effect of energy-efficient technologies on indoor radon concentration is considerably complex and has to be carefully evaluated in respect to radon entry rate and air exchange rate alteration. For the purpose of detailed analysis of radon entry pathways, the unique infiltration experiment has been carried out using the tracer gas (N2O) method application in field conditions. Significant amount of experimental works has been done to provide an independent assessment of radon entry rate andair-exchange rate facilitating the analysis of fundamental factors influencing the indoor radon variations (e.g. indoor-outdoor pressure difference induced by wind; stack effect; heating, ventilation, and air conditioning systems operatio
Název v anglickém jazyce
Radon entry rate analyses using in-situ tracer gas method aplication
Popis výsledku anglicky
Recently, the role of energy savings in indoor air quality deterioration has been extensively emphasized, predominantly in the context of significant air exchange rate reduction as a result of home energy retrofits. In case of refurbishment of existing buildings, the effect of energy-efficient technologies on indoor radon concentration is considerably complex and has to be carefully evaluated in respect to radon entry rate and air exchange rate alteration. For the purpose of detailed analysis of radon entry pathways, the unique infiltration experiment has been carried out using the tracer gas (N2O) method application in field conditions. Significant amount of experimental works has been done to provide an independent assessment of radon entry rate andair-exchange rate facilitating the analysis of fundamental factors influencing the indoor radon variations (e.g. indoor-outdoor pressure difference induced by wind; stack effect; heating, ventilation, and air conditioning systems operatio
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
DN - Vliv životního prostředí na zdraví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TB01SUJB072" target="_blank" >TB01SUJB072: Výzkum ozáření obyvatelstva České republiky od radonu a dalších přírodních zdrojů ionizujícího záření a dopadu existující regulace</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů