Comparative measurements of external radiation exposure using mobile phones, dental ceramic, household salt and conventional personal dosemeters
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F15%3A%230000331" target="_blank" >RIV/86652052:_____/15:#0000331 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.radmeas.2014.11.015" target="_blank" >http://dx.doi.org/10.1016/j.radmeas.2014.11.015</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.radmeas.2014.11.015" target="_blank" >10.1016/j.radmeas.2014.11.015</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparative measurements of external radiation exposure using mobile phones, dental ceramic, household salt and conventional personal dosemeters
Popis výsledku v původním jazyce
This study aimed to investigate whether retrospective dosimeters can provide dose estimates with comparable accuracy as conventional personal dosimeters. Using external source of radiation Cs-137 and an anthropomorphic phantom, we simulated serious irradiation of a human body in anterior-posterior and rotational geometries. Retrospective luminescence dosimetry objects (mobile phones, dental ceramic and household salt) and conventional personal dosemeters (thermoluminescent and electronic) were fixed to the anthropomorphic phantom. The doses obtained were compared with reference values. In most cases, relative deviations between the measured doses and reference values did not exceed 20%. The retrospective and conventional dosemeters measure with similar assuracy in laboratory conditions.
Název v anglickém jazyce
Comparative measurements of external radiation exposure using mobile phones, dental ceramic, household salt and conventional personal dosemeters
Popis výsledku anglicky
This study aimed to investigate whether retrospective dosimeters can provide dose estimates with comparable accuracy as conventional personal dosimeters. Using external source of radiation Cs-137 and an anthropomorphic phantom, we simulated serious irradiation of a human body in anterior-posterior and rotational geometries. Retrospective luminescence dosimetry objects (mobile phones, dental ceramic and household salt) and conventional personal dosemeters (thermoluminescent and electronic) were fixed to the anthropomorphic phantom. The doses obtained were compared with reference values. In most cases, relative deviations between the measured doses and reference values did not exceed 20%. The retrospective and conventional dosemeters measure with similar assuracy in laboratory conditions.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/VF20102015014" target="_blank" >VF20102015014: Výzkum pokročilých metod detekce, stanovení a následné zvládnutí radioaktivní kontaminace</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Measurements
ISSN
1350-4487
e-ISSN
—
Svazek periodika
72
Číslo periodika v rámci svazku
January
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
60-65
Kód UT WoS článku
000348262100008