Determination of tolerance levels in radiotherapy dosimetry based on statistical interference
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F19%3AN0000001" target="_blank" >RIV/86652052:_____/19:N0000001 - isvavai.cz</a>
Výsledek na webu
<a href="https://academic.oup.com/rpd/article/186/2-3/351/5643637" target="_blank" >https://academic.oup.com/rpd/article/186/2-3/351/5643637</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncz233" target="_blank" >10.1093/rpd/ncz233</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of tolerance levels in radiotherapy dosimetry based on statistical interference
Popis výsledku v původním jazyce
The most important dosimetry quantity that is determined at radiotherapy centers is the absorbed dose to water for external beams. Fixed tolerances for absorbed doses measured under reference conditions with an ionization chamber for high-energy photon and electron beams are usually 2 and 3%, respectively, regardless of uncertainties of the input variables and other conditions during evaluation. In reality, this agreement should be evaluated considering the uncertainties of the input variables because they affect the size of the random deviations of the measurements from their true values. The aim of this work was to develop a new approach to evaluate the agreement between measured and reported values based on statistical interference rather than to use fixed tolerance levels. The proposed method considers different scenarios that can occur during the evaluation of agreement. Because the method is described in general, it can be used in all similar situations when partial uncertainties can be established.
Název v anglickém jazyce
Determination of tolerance levels in radiotherapy dosimetry based on statistical interference
Popis výsledku anglicky
The most important dosimetry quantity that is determined at radiotherapy centers is the absorbed dose to water for external beams. Fixed tolerances for absorbed doses measured under reference conditions with an ionization chamber for high-energy photon and electron beams are usually 2 and 3%, respectively, regardless of uncertainties of the input variables and other conditions during evaluation. In reality, this agreement should be evaluated considering the uncertainties of the input variables because they affect the size of the random deviations of the measurements from their true values. The aim of this work was to develop a new approach to evaluate the agreement between measured and reported values based on statistical interference rather than to use fixed tolerance levels. The proposed method considers different scenarios that can occur during the evaluation of agreement. Because the method is described in general, it can be used in all similar situations when partial uncertainties can be established.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/FV20411" target="_blank" >FV20411: Radioterapeutický plánovací systém - optimalizace nejmodernějších algoritmů pro 3D výpočet dávky od externích svazků v těle pacienta a jejich integrace do nové generace plánovacího systému.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation protection dosimetry
ISSN
0144-8420
e-ISSN
1742-3406
Svazek periodika
186
Číslo periodika v rámci svazku
2-3
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
367-372
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85082881494