Comparison of different techniques for evaluation of dose distributions in radiotherapy using radiochromic EBT3 films
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F19%3AN0000010" target="_blank" >RIV/86652052:_____/19:N0000010 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064211:_____/19:W0002018
Výsledek na webu
<a href="https://academic.oup.com/rpd/article/186/2-3/357/5618731" target="_blank" >https://academic.oup.com/rpd/article/186/2-3/357/5618731</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncz231" target="_blank" >10.1093/rpd/ncz231</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of different techniques for evaluation of dose distributions in radiotherapy using radiochromic EBT3 films
Popis výsledku v původním jazyce
In radiotherapy radiochromic films can be used for verification of delivery of dose distributions calculated by treatment planning systems. The main objective of this work was to compare three different techniques for evaluation of dose distributions for prostate cancer treatment plans using radiochromic EBT3 films. These techniques are: red channel evaluation taking into account only a response of irradiated film, red channel evaluation taking into account a response of unirradiated and irradiated film and multichannel evaluation in FilmQA software. Comparison showed that gamma analysis passing rates strongly depend on evaluation technique and on a model of scanner for digitizing films. The highest gamma passing rates were obtained with red channel evaluation taking into account a response of unirradiated and irradiated film using Epson V750 scanner (Rcor) and multichannel evaluation in FilmQA using Epson 11000XL scanner.
Název v anglickém jazyce
Comparison of different techniques for evaluation of dose distributions in radiotherapy using radiochromic EBT3 films
Popis výsledku anglicky
In radiotherapy radiochromic films can be used for verification of delivery of dose distributions calculated by treatment planning systems. The main objective of this work was to compare three different techniques for evaluation of dose distributions for prostate cancer treatment plans using radiochromic EBT3 films. These techniques are: red channel evaluation taking into account only a response of irradiated film, red channel evaluation taking into account a response of unirradiated and irradiated film and multichannel evaluation in FilmQA software. Comparison showed that gamma analysis passing rates strongly depend on evaluation technique and on a model of scanner for digitizing films. The highest gamma passing rates were obtained with red channel evaluation taking into account a response of unirradiated and irradiated film using Epson V750 scanner (Rcor) and multichannel evaluation in FilmQA using Epson 11000XL scanner.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
1742-3406
Svazek periodika
186
Číslo periodika v rámci svazku
2-3
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
357-361
Kód UT WoS článku
000530582200043
EID výsledku v databázi Scopus
2-s2.0-85082780299