Postal TLD audit of heterogeneity corrections in radiotherapy in the Czech Republic
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F19%3AN0000038" target="_blank" >RIV/86652052:_____/19:N0000038 - isvavai.cz</a>
Výsledek na webu
<a href="https://academic.oup.com/rpd/article/186/2-3/373/5675500" target="_blank" >https://academic.oup.com/rpd/article/186/2-3/373/5675500</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncz234" target="_blank" >10.1093/rpd/ncz234</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Postal TLD audit of heterogeneity corrections in radiotherapy in the Czech Republic
Popis výsledku v původním jazyce
In the Czech Republic, a more advanced version of postal audit in radiotherapy (RT) is available. It covers dose measurements with thermoluminescent dosemeters (TLD) in more complex conditions of irradiation, when dose distribution is affected by heterogeneities in the irradiated volume. Relative deviation between doses measured with TLDs and doses stated by RT centre should not exceed 3%. During 2015–2017, all Czech RT centres equipped with modern linear accelerators were subjected to this more advanced TLD audit. A total of 70% of participants complied with the limit of 3% in the first round of this audit.
Název v anglickém jazyce
Postal TLD audit of heterogeneity corrections in radiotherapy in the Czech Republic
Popis výsledku anglicky
In the Czech Republic, a more advanced version of postal audit in radiotherapy (RT) is available. It covers dose measurements with thermoluminescent dosemeters (TLD) in more complex conditions of irradiation, when dose distribution is affected by heterogeneities in the irradiated volume. Relative deviation between doses measured with TLDs and doses stated by RT centre should not exceed 3%. During 2015–2017, all Czech RT centres equipped with modern linear accelerators were subjected to this more advanced TLD audit. A total of 70% of participants complied with the limit of 3% in the first round of this audit.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
1742-3406
Svazek periodika
186
Číslo periodika v rámci svazku
2-3
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
4
Strana od-do
373-376
Kód UT WoS článku
000530582200046
EID výsledku v databázi Scopus
2-s2.0-85082780448