Emergency preparedness of gamma spectrometry laboratories
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F19%3AN0000060" target="_blank" >RIV/86652052:_____/19:N0000060 - isvavai.cz</a>
Výsledek na webu
<a href="https://academic.oup.com/rpd/article/186/2-3/332/5614304" target="_blank" >https://academic.oup.com/rpd/article/186/2-3/332/5614304</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncz228" target="_blank" >10.1093/rpd/ncz228</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Emergency preparedness of gamma spectrometry laboratories
Popis výsledku v původním jazyce
Currently, the territorial Radiation Monitoring Network (RMN) of the Czech Republic consists of seven laboratories equipped with gamma spectrometry High Purity Germanium (HPGe) detectors. From 2007 to 2018, five emergency exercises were carried out to test the sample throughput of these facilities and their staff. The main objective was to identify weaknesses and problem areas in the whole process from the moment of obtaining the samples to logging the results into the central RMN database. The long-term aim of these exercises is to optimize emergency response procedures. The most important factor limiting laboratory capacity is the lack of qualified personnel. The exercises showed that in the current state, these laboratories would be able to operate in 12-hour shifts for 14 days and analyze 1700 samples per day. Emergency exercises have highlighted the fact that this type of exercise should be repeated periodically in order to monitor the performance and analytical capabilities of RMN.
Název v anglickém jazyce
Emergency preparedness of gamma spectrometry laboratories
Popis výsledku anglicky
Currently, the territorial Radiation Monitoring Network (RMN) of the Czech Republic consists of seven laboratories equipped with gamma spectrometry High Purity Germanium (HPGe) detectors. From 2007 to 2018, five emergency exercises were carried out to test the sample throughput of these facilities and their staff. The main objective was to identify weaknesses and problem areas in the whole process from the moment of obtaining the samples to logging the results into the central RMN database. The long-term aim of these exercises is to optimize emergency response procedures. The most important factor limiting laboratory capacity is the lack of qualified personnel. The exercises showed that in the current state, these laboratories would be able to operate in 12-hour shifts for 14 days and analyze 1700 samples per day. Emergency exercises have highlighted the fact that this type of exercise should be repeated periodically in order to monitor the performance and analytical capabilities of RMN.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10511 - Environmental sciences (social aspects to be 5.7)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
1742-3406
Svazek periodika
186
Číslo periodika v rámci svazku
2-3
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
332–336
Kód UT WoS článku
000530582200038
EID výsledku v databázi Scopus
2-s2.0-85082779902