Retrospective dose reconstruction with mobile phones and chip cards
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F19%3AN0000067" target="_blank" >RIV/86652052:_____/19:N0000067 - isvavai.cz</a>
Výsledek na webu
<a href="https://academic.oup.com/rpd/article/186/2-3/206/5620702?searchresult=1" target="_blank" >https://academic.oup.com/rpd/article/186/2-3/206/5620702?searchresult=1</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncz203" target="_blank" >10.1093/rpd/ncz203</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Retrospective dose reconstruction with mobile phones and chip cards
Popis výsledku v původním jazyce
Mobile phones and common chip cards are very widespread items that almost everyone owns. They contain some radiation sensitive materials that can be used for dosimetry based on stimulated luminescence. We investigated and compared reproducibility, dose response, and fading of luminescence signal for the particular materials. Subsequently, we performed an experiment of a dose reconstruction using mobile phones and chip cards which were fixed to a slab phantom and irradiated by a 137Cs radiation source in our laboratory. Doses obtained were compared with reference values. The materials investigated can be used for dosimetry in cases of serious radiation accidents or malevolent acts with radioactive materials, when it is extremely important to identify as quickly as possible individuals who received high radiation doses.
Název v anglickém jazyce
Retrospective dose reconstruction with mobile phones and chip cards
Popis výsledku anglicky
Mobile phones and common chip cards are very widespread items that almost everyone owns. They contain some radiation sensitive materials that can be used for dosimetry based on stimulated luminescence. We investigated and compared reproducibility, dose response, and fading of luminescence signal for the particular materials. Subsequently, we performed an experiment of a dose reconstruction using mobile phones and chip cards which were fixed to a slab phantom and irradiated by a 137Cs radiation source in our laboratory. Doses obtained were compared with reference values. The materials investigated can be used for dosimetry in cases of serious radiation accidents or malevolent acts with radioactive materials, when it is extremely important to identify as quickly as possible individuals who received high radiation doses.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
<a href="/cs/project/VI20152020033" target="_blank" >VI20152020033: Metodiky pro stanovení radiačních dávek osob v kontextu hrozby jaderného a radiologického terorismu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
1742-3406
Svazek periodika
186
Číslo periodika v rámci svazku
2-3
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
206-210
Kód UT WoS článku
000530582200013
EID výsledku v databázi Scopus
2-s2.0-85082779743