Comparison of luminescence detectors of Al2O3:C, CaF2:Mn, LiF:Mg,Cu,P and quartz with respect to retrospective dose reconstructions using bricks
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F21%3AN0000006" target="_blank" >RIV/86652052:_____/21:N0000006 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/abs/pii/S0969804321003444" target="_blank" >https://www.sciencedirect.com/science/article/abs/pii/S0969804321003444</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.apradiso.2021.109947" target="_blank" >10.1016/j.apradiso.2021.109947</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of luminescence detectors of Al2O3:C, CaF2:Mn, LiF:Mg,Cu,P and quartz with respect to retrospective dose reconstructions using bricks
Popis výsledku v původním jazyce
In the aftermath of an orphan radiation source find, a complex retrospective dose reconstruction can be required to estimate doses of persons who were staying in the vicinity. In retrospective dose reconstructions based on luminescence measurements of quartz extracted from bricks, high sensitivity thermoluminescence detectors (TLD) can be used as an ancillary tool for dose distribution measurements or natural radiation background measurement. We investigated the potential and limits of Al2O3:C, CaF2:Mn and LiF:Mg,Cu,P detectors for such applications. We measured depth-dose profiles in bricks using quartz and the TLDs. We factored in important dosimetry characteristics such as dose response, energy response and detection threshold. The work included Monte Carlo simulations. Depth-dose profiles and radiation spectra inside of the bricks were calculated for purposes of comparison and interpretation. The measurements and calculations were performed for two different photon spectra with mean energies of 662 and 118 keV. As regards comparison of the measured and Monte Carlo calculated depth-dose profiles, the best agreement was found for LiF:Mg,Cu,P. Quartz, Al2O3:C and CaF2:Mn tend to overestimate dose for lower photon energies and greater depths in bricks. The overestimation was the most marked for CaF2:Mn. For measurements related to quartz, especially for natural radiation background dose measurement, the most suitable TLDs are Al2O3:C and LiF:Mg,Cu,P. CaF2:Mn is the least useful material.
Název v anglickém jazyce
Comparison of luminescence detectors of Al2O3:C, CaF2:Mn, LiF:Mg,Cu,P and quartz with respect to retrospective dose reconstructions using bricks
Popis výsledku anglicky
In the aftermath of an orphan radiation source find, a complex retrospective dose reconstruction can be required to estimate doses of persons who were staying in the vicinity. In retrospective dose reconstructions based on luminescence measurements of quartz extracted from bricks, high sensitivity thermoluminescence detectors (TLD) can be used as an ancillary tool for dose distribution measurements or natural radiation background measurement. We investigated the potential and limits of Al2O3:C, CaF2:Mn and LiF:Mg,Cu,P detectors for such applications. We measured depth-dose profiles in bricks using quartz and the TLDs. We factored in important dosimetry characteristics such as dose response, energy response and detection threshold. The work included Monte Carlo simulations. Depth-dose profiles and radiation spectra inside of the bricks were calculated for purposes of comparison and interpretation. The measurements and calculations were performed for two different photon spectra with mean energies of 662 and 118 keV. As regards comparison of the measured and Monte Carlo calculated depth-dose profiles, the best agreement was found for LiF:Mg,Cu,P. Quartz, Al2O3:C and CaF2:Mn tend to overestimate dose for lower photon energies and greater depths in bricks. The overestimation was the most marked for CaF2:Mn. For measurements related to quartz, especially for natural radiation background dose measurement, the most suitable TLDs are Al2O3:C and LiF:Mg,Cu,P. CaF2:Mn is the least useful material.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
<a href="/cs/project/VI20192022139" target="_blank" >VI20192022139: Retrospektivní dozimetrie pro incidenty se ztracenými zdroji záření</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Radiation and Isotopes
ISSN
0969-8043
e-ISSN
1872-9800
Svazek periodika
178
Číslo periodika v rámci svazku
December
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
109947
Kód UT WoS článku
000701739500009
EID výsledku v databázi Scopus
2-s2.0-85114773609