Organic and inorganic carbon storage in riparian zones of Central European rivers A comparison of methods for their determination
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652079%3A_____%2F24%3A00584907" target="_blank" >RIV/86652079:_____/24:00584907 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14310/24:00135563
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S1040618223003804?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S1040618223003804?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.quaint.2023.12.008" target="_blank" >10.1016/j.quaint.2023.12.008</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Organic and inorganic carbon storage in riparian zones of Central European rivers A comparison of methods for their determination
Popis výsledku v původním jazyce
Increasing interest in carbon storage and fluxes in river systems opens space for comparison of methods for the determination of total organic carbon (TOC) and inorganic carbon (TIC) in soil/sediment samples. We analysed 150 soil (leptosols and fluvisols) and sediment samples from three rivers using methods mostly used in studies. Widely used dry combustion method (with CO2 detection) for determination of TOC and TIC was compared with other methods for determination TOC (modified Walkley-Black method), total organic matter (TOM determined by loss on ignition) and TIC (calcimeter, loss on ignition). Furthermore, we proposed a procedure for calculation TOC from TOM together with relative standard deviation resulting from this conversion. Our results showed that the modified Walkley-Black method provides almost identical results of TOC as dry combustion and therefore can be used as an alternative method for the determination of TOC. A strong correlation was found between TOC and TOM (R2 = 0.97 for both methods for determination TOC). The mean relative deviation of TOC values resulting from calculation TOC based on TOM varied between 10.1% and 14.5%. Thus, the calculation TOC from TOM is possible, but only with deviations referred to above. We suggest that for samples with TOM values below 1%, the TOC values cannot be reliably calculated, and in this case, the dry combustion or modified Walkley-Black method must be used for TOC determination. TIC values determined by the three methods vary to a greater extent than those of organic carbon. We assume that in the case of low TIC content (below 1%), various methods can give markedly different results. Due to the higher relative standard deviation in case of dry combustion, it is probably better to use a calcimeter for the determination of TIC in samples with TIC content below 1%.
Název v anglickém jazyce
Organic and inorganic carbon storage in riparian zones of Central European rivers A comparison of methods for their determination
Popis výsledku anglicky
Increasing interest in carbon storage and fluxes in river systems opens space for comparison of methods for the determination of total organic carbon (TOC) and inorganic carbon (TIC) in soil/sediment samples. We analysed 150 soil (leptosols and fluvisols) and sediment samples from three rivers using methods mostly used in studies. Widely used dry combustion method (with CO2 detection) for determination of TOC and TIC was compared with other methods for determination TOC (modified Walkley-Black method), total organic matter (TOM determined by loss on ignition) and TIC (calcimeter, loss on ignition). Furthermore, we proposed a procedure for calculation TOC from TOM together with relative standard deviation resulting from this conversion. Our results showed that the modified Walkley-Black method provides almost identical results of TOC as dry combustion and therefore can be used as an alternative method for the determination of TOC. A strong correlation was found between TOC and TOM (R2 = 0.97 for both methods for determination TOC). The mean relative deviation of TOC values resulting from calculation TOC based on TOM varied between 10.1% and 14.5%. Thus, the calculation TOC from TOM is possible, but only with deviations referred to above. We suggest that for samples with TOM values below 1%, the TOC values cannot be reliably calculated, and in this case, the dry combustion or modified Walkley-Black method must be used for TOC determination. TIC values determined by the three methods vary to a greater extent than those of organic carbon. We assume that in the case of low TIC content (below 1%), various methods can give markedly different results. Due to the higher relative standard deviation in case of dry combustion, it is probably better to use a calcimeter for the determination of TIC in samples with TIC content below 1%.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10508 - Physical geography
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Quaternary International
ISSN
1040-6182
e-ISSN
1873-4553
Svazek periodika
681
Číslo periodika v rámci svazku
JAN
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
44-51
Kód UT WoS článku
001168024300001
EID výsledku v databázi Scopus
2-s2.0-85180326144