Assessment of the impact of sampler housing on indoor passive air sampler measurements of SVOCs
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652079%3A_____%2F24%3A00617330" target="_blank" >RIV/86652079:_____/24:00617330 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14310/24:00139262
Výsledek na webu
<a href="https://www.oaepublish.com/articles/jeea.2023.39" target="_blank" >https://www.oaepublish.com/articles/jeea.2023.39</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.20517/jeea.2023.39" target="_blank" >10.20517/jeea.2023.39</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Assessment of the impact of sampler housing on indoor passive air sampler measurements of SVOCs
Popis výsledku v původním jazyce
Passive air sampling (PAS) using a polyurethane foam (PUF) sorbent is a widely used technique to characterize air concentrations of semi-volatile organic compounds (SVOCs) in indoor environments, however, there is little consensus on the type of housing used in sampler housings and how sampler masses are converted to air concentration. We systematically evaluate the three types of PUF-PAS sampler housings most commonly used indoors, and characterize uptake rates for > 50 SVOCs, covering legacy persistent organic pollutants, pesticides, combustion by-products, and flame retardants for all three housing types. There is a clear association between the amount of shielding of the PUF disk and equivalent air volumes for PUF-PAS, with median sampling rates for double-bowl housings of 0.72 m3/day (0.62-0.92 m3/day), 1.3 m3/day (1.0-1.7 m3/day) for single bowl, and 1.8 m3/day (1.4-2.2 m3/day) for PUFs without any housing. Combining these outcomes with a meta-analysis of existing data on PUF-PAS indoor uptake, we provide recommendations for the range of applicability and selection of sampling rates for PUF-PAS in indoor environments.
Název v anglickém jazyce
Assessment of the impact of sampler housing on indoor passive air sampler measurements of SVOCs
Popis výsledku anglicky
Passive air sampling (PAS) using a polyurethane foam (PUF) sorbent is a widely used technique to characterize air concentrations of semi-volatile organic compounds (SVOCs) in indoor environments, however, there is little consensus on the type of housing used in sampler housings and how sampler masses are converted to air concentration. We systematically evaluate the three types of PUF-PAS sampler housings most commonly used indoors, and characterize uptake rates for > 50 SVOCs, covering legacy persistent organic pollutants, pesticides, combustion by-products, and flame retardants for all three housing types. There is a clear association between the amount of shielding of the PUF disk and equivalent air volumes for PUF-PAS, with median sampling rates for double-bowl housings of 0.72 m3/day (0.62-0.92 m3/day), 1.3 m3/day (1.0-1.7 m3/day) for single bowl, and 1.8 m3/day (1.4-2.2 m3/day) for PUFs without any housing. Combining these outcomes with a meta-analysis of existing data on PUF-PAS indoor uptake, we provide recommendations for the range of applicability and selection of sampling rates for PUF-PAS in indoor environments.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/EF17_043%2F0009632" target="_blank" >EF17_043/0009632: CETOCOEN Excellence</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Environmental Exposure Assessment
ISSN
2771-5949
e-ISSN
2771-5949
Svazek periodika
3
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
14
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85186204421