Characterization of kHz Repetition Rate Laser-Driven Electron Beams by an Inhomogeneous Field Dipole Magnet Spectrometer
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2FCZ______%3A_____%2F24%3AN0000015" target="_blank" >RIV/CZ______:_____/24:N0000015 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.webofscience.com/wos/woscc/full-record/WOS:001383924100001" target="_blank" >https://www.webofscience.com/wos/woscc/full-record/WOS:001383924100001</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/photonics11121208" target="_blank" >10.3390/photonics11121208</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Characterization of kHz Repetition Rate Laser-Driven Electron Beams by an Inhomogeneous Field Dipole Magnet Spectrometer
Popis výsledku v původním jazyce
We demonstrate a method to characterize the beam energy, transverse profile, charge, and dose of a pulsed electron beam generated by a 1 kHz TW laser-plasma accelerator. The method is based on imaging with a scintillating screen in an inhomogeneous, orthogonal magnetic field produced by a wide-gap magnetic dipole. Numerical simulations were developed to reconstruct the electron beam parameters accurately. The method has been experimentally verified and calibrated using a medical LINAC. The energy measurement accuracy in the 6-20 MeV range is proven to be better than 10%. The radiation dose has been calibrated by a water-equivalent phantom, RW3, showing a linear response of the method within 2% in the 0.05-0.5 mGy/pulse range.
Název v anglickém jazyce
Characterization of kHz Repetition Rate Laser-Driven Electron Beams by an Inhomogeneous Field Dipole Magnet Spectrometer
Popis výsledku anglicky
We demonstrate a method to characterize the beam energy, transverse profile, charge, and dose of a pulsed electron beam generated by a 1 kHz TW laser-plasma accelerator. The method is based on imaging with a scintillating screen in an inhomogeneous, orthogonal magnetic field produced by a wide-gap magnetic dipole. Numerical simulations were developed to reconstruct the electron beam parameters accurately. The method has been experimentally verified and calibrated using a medical LINAC. The energy measurement accuracy in the 6-20 MeV range is proven to be better than 10%. The radiation dose has been calibrated by a water-equivalent phantom, RW3, showing a linear response of the method within 2% in the 0.05-0.5 mGy/pulse range.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_019%2F0000789" target="_blank" >EF16_019/0000789: Pokročilý výzkum s využitím fotonů a částic vytvořených vysoce intenzivními lasery</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
PHOTONICS
ISSN
—
e-ISSN
2304-6732
Svazek periodika
11
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
16
Strana od-do
1208
Kód UT WoS článku
001383924100001
EID výsledku v databázi Scopus
2-s2.0-85213321921