Analýza případu vnitřní kontaminace radioizotopy kobaltu
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2FQ01_____%3A_____%2F07%3A%230000065" target="_blank" >RIV/Q01_____:_____/07:#0000065 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/07:04153296
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of a Case of Internal Contamination with Cobalt Radioisotopes
Popis výsledku v původním jazyce
Internal contamination by compounds of cobalt radioisotopes occurs time to time at nuclear power plants. Intakes and committed effective doses are estimated by biokinetic models described in ICRP publications. The paper deals with a case of internal contamination of a worker engaged in a maintenance task at NPP Dukovany. In this case significant discrepancy was observed between intakes based on various datasets (whole body counting, analysis of urine and faeces) when default model setting was used. Thereason of this phenomenon was searched for. Three different least square methods of fits were used to find out possible effect of a fitting method, The measured data were fitted by set of biokinetic functions, which covered all intake ways (ingestion, inhalation) and types (M, S, different AMADs and different f1) of the contaminant. The biokinetic model of cobalt needs further improvements as to find better agreement between data fit from direct measurements and bioassay.
Název v anglickém jazyce
Analysis of a Case of Internal Contamination with Cobalt Radioisotopes
Popis výsledku anglicky
Internal contamination by compounds of cobalt radioisotopes occurs time to time at nuclear power plants. Intakes and committed effective doses are estimated by biokinetic models described in ICRP publications. The paper deals with a case of internal contamination of a worker engaged in a maintenance task at NPP Dukovany. In this case significant discrepancy was observed between intakes based on various datasets (whole body counting, analysis of urine and faeces) when default model setting was used. Thereason of this phenomenon was searched for. Three different least square methods of fits were used to find out possible effect of a fitting method, The measured data were fitted by set of biokinetic functions, which covered all intake ways (ingestion, inhalation) and types (M, S, different AMADs and different f1) of the contaminant. The biokinetic model of cobalt needs further improvements as to find better agreement between data fit from direct measurements and bioassay.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DL - Jaderné odpady, radioaktivní znečištění a kontrola
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiatrion Protection Dosimetry
ISSN
0144-8420
e-ISSN
—
Svazek periodika
125
Číslo periodika v rámci svazku
1-4
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
4
Strana od-do
527-530
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—