Filtry
Breakdown of DC Diaphragm Discharge in Liquids
This contribution present results of breakdown in DC diaphragm discharge in NaCl water solution. The breakdown voltage was estimated 1100-1300 V in wide range of conductivities (200-1200 microS.cm-1) with breakdown...
BL - Fyzika plasmatu a výboje v plynech
- 2007 •
- D
Rok uplatnění
D - Stať ve sborníku
Breakdown of DC Diaphragm Discharge in Solutions of Alkaline Metals
This contribution shows results obtained from the electrical measurements of the DC diaphragm discharge with the focus on the discharge ignition. The determined breakdown voltage beheld into the range of 1100-1300 V in wide range of...
BL - Fyzika plasmatu a výboje v plynech
- 2007 •
- D
Rok uplatnění
D - Stať ve sborníku
Breakdown of DC Diaphragm Discharge in Solutions of Alkaline Metals
This contribution shows results obtained from the electrical measurements of the DC diaphragm discharge with the focus on the discharge ignition. The determined breakdown voltage beheld into the range of 1100-1300 V in wide range of...
BL - Fyzika plasmatu a výboje v plynech
- 2007 •
- D
Rok uplatnění
D - Stať ve sborníku
Breakdown of DC Diaphragm Discharge in Selected Solutions of Alcaline Metals
This contribution shows results obtained from the electrical measurements of the DC diaphragm discharge with the focus on the discharge ignition. The determined breakdown voltage beheld into the range of 1100-1300 V in wide range of...
BL - Fyzika plasmatu a výboje v plynech
- 2007 •
- D
Rok uplatnění
D - Stať ve sborníku
Application Possibilities of Fused Filament Fabrication Technology for High-Voltage and Medium-Voltage Insulation Systems
conducted - atmospheric impulse test with positive polarity, short-term AC and DC breakdown strength tests and measurement of partial discharges. Based on acquired results, the optimal material for unipolar stresses (D...
Electrical and electronic engineering
- 2019 •
- D •
- Odkaz
Rok uplatnění
D - Stať ve sborníku
Výsledek na webu
Breakdown of the DC Diaphragm Discharge in Liquids
This paper presents results of breakdown phenomenon in the DC diaphragm discharge generated in water solutions of various electrolytes. The determined breakdown breakdown current was 20-50 mA. Both voltage and curr...
BL - Fyzika plasmatu a výboje v plynech
- 2007 •
- D
Rok uplatnění
D - Stať ve sborníku
Electrical Parameters and Temperature of the Breakdown of Air in Superimposed AC and DC Fields
JA - Elektronika a optoelektronika, elektrotechnika
- 1993 •
- X
Rok uplatnění
X - Nezařazeno
Monte-Carlo simulation of the initial stage of the DC electrical breakdown of a gas
BL - Fyzika plasmatu a výboje v plynech
- 1997 •
- X
Rok uplatnění
X - Nezařazeno
Monte-Carlo Simulation of the Initial Stage of the DC Electrical Breakdown of a Gas
BL - Fyzika plasmatu a výboje v plynech
- 1998 •
- X
Rok uplatnění
X - Nezařazeno
Optical and Electrical Characterization of DC Diaphragm Discharge in Liquids
obtained from the electrical measurements of the DC diaphragm discharge with the focus on the discharge ignition. The determined breakdown voltage beheld into the range of 1100-1300 or less independently on the electrolyte kind. Th...
BL - Fyzika plasmatu a výboje v plynech
- 2007 •
- D
Rok uplatnění
D - Stať ve sborníku
- 1 - 10 z 30 137