Filtry
Verification and validation of the R2Smesh approach for the calculation of high resolution shutdown dose rate distributions
The well validated Rigorous-2-Step (R2S) approach for the calculation of decay gamma shutdown dose rates has been extended utilizing mesh tally capabilities Neutron Generator) shutdown dose rate b...
Nuclear physics
- 2012 •
- Jimp •
- Odkaz
Rok uplatnění
Jimp - Článek v periodiku v databázi Web of Science
Výsledek na webu
Shutdown dose rate analysis for the European TBM system in ITER
require the shutdown dose rate level to be less than 100 ?Sv/h after a waiting time of 106 s (to 12 days). Qualified shutdown dose rate calculations shutdown periods, the activation give...
BF - Elementární částice a fyzika vysokých energií
- 2012 •
- Jx •
- Odkaz
Rok uplatnění
Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
Výsledek na webu
Sensitivity of ambient dose equivalent to the concentration of cobalt impurity present in stainless steel
. These hard gammas will be mostly responsible for the dose rates seen in the next few tens and estimate the dose contributed by it. Monte Carlo simulations are performed where and epithermal neutrons. The ambient dose<...
Fluids and plasma physics (including surface physics)
- 2018 •
- D •
- Odkaz
Rok uplatnění
D - Stať ve sborníku
Výsledek na webu
Shutdowns of denitrifying bioreactor with wood-based fill media
The contribution discusses shutdowns of denitrifying bioreactors with wood-based fill media...
Construction engineering, Municipal and structural engineering
- 2019 •
- O
Rok uplatnění
O - Ostatní výsledky
Terrestrial radiation
K, U, Th source of terrestrial natural radiation, terrestrial gamma rays, dose rate of rock environment, dose rate of nuclear fallout, instruments and methods, geophysical dose rate measurement, <...
Geology
- 2020 •
- C •
- Odkaz
Rok uplatnění
C - Kapitola v odborné knize
Výsledek na webu
Denitrifying woodchip bioreactor shutdown during dry periods
The contribution is focused on wet shutdown of denitrifying woodchip bioreactor during dry period.
Other natural sciences
- 2018 •
- D •
- Odkaz
Rok uplatnění
D - Stať ve sborníku
Výsledek na webu
Dose rate measurement of aerosol filtr and the possibility to use it for radiation situation evaluation
The article is focused on fast evaluation of radiation situation in the aerosol sampling place by means of dose rate measurement. On the basis of long term monitoring of dose rate in filters critical values of ...
JF - Jaderná energetika
- 2007 •
- D
Rok uplatnění
D - Stať ve sborníku
Assessment of Typical Shutdowns in CHP Plant
assessed by key availability parameters e.g., number of shutdowns and shutdown time of shutdowns have been assessed. Moreover, the paper presents the solutions to improve......
Electrical and electronic engineering
- 2022 •
- D •
- Odkaz
Rok uplatnění
D - Stať ve sborníku
Výsledek na webu
High dose rate versus low dose rate brachytherapy in the treatment of tongue carcinoma - a radiobiological study
Radiobiological study comparing tumor control (TCP) and risk of acute and late complications (NTCP) of low dose rate (LDR) brachytherapy and high dose rate (HDR) brachytehrapy in the treatment of tongue cancer. HDR...
FD - Onkologie a hematologie
- 2009 •
- Jx
Rok uplatnění
Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
Environmental detector for wide-range dose rate measurement
Wide-range gamma radiation detector for ambient dose rate measurement...
JF - Jaderná energetika
- 2015 •
- Gfunk
Rok uplatnění
Gfunk - Funkční vzorek
- 1 - 10 z 67 546