Filtry
Stress-Strain Analysis of Pelvic Bone With Press-Fit Cup
press-fit cup and its interaction in the pelvis-cup-head system. It describes states of the CLS press-fit cup. The problem was solved by numerical simulation of the cup applied ...
JR - Ostatní strojírenství
- 2007 •
- D
Rok uplatnění
D - Stať ve sborníku
ABG Cementless THR: Description of Implant, Medium-term Results
The autors present medium- term clinical results and radiografic evaluation of the implantation of cementless ABG total hip replacement. The implant is made from titanium alloy with a press-fit acerabular cup. The outer sur...
FI - Traumatologie a ortopedie
- 1999 •
- Jx
Rok uplatnění
Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
Is the kinematic Orthopilot press-fit cup navigation suitable for use after petvis or actabular injuries
Kinematic navigation, Orthopilot, pelvis, acetabular injuries...
FI - Traumatologie a ortopedie
- 2003 •
- D
Rok uplatnění
D - Stať ve sborníku
Evaluation of acetabular cup initial fixation by using resonance frequency principle
the information about the absolute stiffness of the press-fit implant..The clinical practice shows that the loosening of acetabular cups is more frequent than stem loosening. With standard cups, the incidence of d...
JR - Ostatní strojírenství
- 2015 •
- Jx •
- Odkaz
Rok uplatnění
Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
Výsledek na webu
Pressing station for a shock absorber spring supporting cup
Carrying out modifications consisting in completing the mechanical parts, enabling inserting and pressing the cup onto the shock absorber in its lower section. The extended pressing adapter is removable....
JQ - Strojní zařízení a nástroje
- 2014 •
- Gprot
Rok uplatnění
Gprot - Prototyp
Influence of femoral head size and head/cup fit on mechanical interaction between the head and the cup of the THR
The purpose of this paper is to perform the stress-strain analysis of the hip joint with THR applied and to specify the influence of the size of femoral head and head/cup fit on the contact area and the value and distribution of the...
FI - Traumatologie a ortopedie
- 2006 •
- D
Rok uplatnění
D - Stať ve sborníku
Function prototype of cleaning teat cup
Cleaning teat cup is determined to teats mechanical cleanings prior milking. The cleaning teat cup is fitted by rotary brush with helix ? shaped hairs placed inside is placed in the cylindrical case in rotary-free mode. The...
GG - Chov hospodářských zvířat
- 2007 •
- X
Rok uplatnění
X - Nezařazeno
Realization of the Press Fit with Use of Constrain Equations
The contribution deals and describes the possibilities of modeling of press fit by Constrain Equations. It is the alternative way of modeling of the press fit without use of contact elements. The whole task is real...
JR - Ostatní strojírenství
- 2007 •
- D
Rok uplatnění
D - Stať ve sborníku
Modeling of the Press Fit by Constrain Equation
The contribution deals and describes the possibilities of modeling of press fit by Constrain Equations. It is the alternative way of modeling of the press fit without use of contact elements. The whole task is real...
JR - Ostatní strojírenství
- 2007 •
- D
Rok uplatnění
D - Stať ve sborníku
Loading and fitting impact against reliability of torqe transmission by press - fitted joint
The article demonstrates the reliability evalution of the Friction Bond depending on a various random loading and a fitting using advanced fully probabilistic approach.The probability of serviceability, i.e. reliability of torqu transmission...
JQ - Strojní zařízení a nástroje
- 2002 •
- D
Rok uplatnění
D - Stať ve sborníku
- 1 - 10 z 19 584