Quantitative Risk Assessment of Bacillus cereus Growth during the Warming of Thawed Pasteurized Human Banked Milk Using a Predictive Mathematical Model
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00027022%3A_____%2F22%3AN0000007" target="_blank" >RIV/00027022:_____/22:N0000007 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11150/22:10443723 RIV/00179906:_____/22:10443723
Result on the web
<a href="https://www.mdpi.com/2304-8158/11/7/1037" target="_blank" >https://www.mdpi.com/2304-8158/11/7/1037</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/foods11071037" target="_blank" >10.3390/foods11071037</a>
Alternative languages
Result language
angličtina
Original language name
Quantitative Risk Assessment of Bacillus cereus Growth during the Warming of Thawed Pasteurized Human Banked Milk Using a Predictive Mathematical Model
Original language description
Bacillus cereus is relatively resistant to pasteurization. We assessed the risk of B. cereus growth during warming and subsequent storage of pasteurized banked milk (PBM) in the warmed state using a predictive mathematical model. Holder pasteurization followed by storage below −18 ◦C was used. Temperature maps, water activity values, and B. cereus growth in artificially inoculated PBM were obtained during a simulation of manipulation of PBM after its release from a Human Milk Bank. As a real risk level, we chose a B. cereus concentration of 100 CFU/mL; the risk was assessed for three cases: 1. For an immediate post pasteurization B. cereus concentration below 1 CFU/mL (level of detection); 2. For a B. cereus concentration of 10 CFU/mL, which is allowed in some countries; 3. For a B. cereus concentration of 50 CFU/mL, which is approved for milk formulas. In the first and second cases, no risk was detected after 1 h of storage in the warmed state, while after 2 h of storage, B. cereus concentrations of 102 CFU/mL were occasionally encountered. In the third case, exceeding the B. cereus concentration of 102 CFU/mL could be regularly expected after 2 h of storage. Based on these results, we recommend that post-pasteurization bacteriological analysis beperformed as recommended by the European Milk Bank Association (EMBA) and using warmed PBM within 1 h after warming (no exceptions)
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
21101 - Food and beverages
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Foods
ISSN
2304-8158
e-ISSN
—
Volume of the periodical
11
Issue of the periodical within the volume
1037
Country of publishing house
CH - SWITZERLAND
Number of pages
14
Pages from-to
—
UT code for WoS article
000781286800001
EID of the result in the Scopus database
—