Focal control of non-invasive deep brain stimulation using multipolar temporal interference
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F25%3A00082300" target="_blank" >RIV/00159816:_____/25:00082300 - isvavai.cz</a>
Result on the web
<a href="https://link.springer.com/article/10.1186/s42234-025-00169-6" target="_blank" >https://link.springer.com/article/10.1186/s42234-025-00169-6</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1186/s42234-025-00169-6" target="_blank" >10.1186/s42234-025-00169-6</a>
Alternative languages
Result language
angličtina
Original language name
Focal control of non-invasive deep brain stimulation using multipolar temporal interference
Original language description
Temporal interference (TI) is a method of non-invasive brain stimulation using transcutaneous electrodes which allows the targeting and modulation of deeper brain structures, not normally associated with non-invasive simulation, while avoiding unwanted stimulation of shallower cortical structures. The properties of TI have been previously demonstrated, however, the problem of decoupling stimulation focality from stimulation intensity has not yet been well addressed. In this paper, we provide a possible novel solution, multipolar TI (mTI), which allows increased independent control over both the size of the stimulated region and the stimulation intensity. The mTI method uses multiple carrier frequencies to create multiple overlapping amplitude-modulated envelopes, rather than using one envelope as in standard TI. The study presents an explanation of the concept of mTI along with experimental data gathered from Rhesus macaques and mice. We improved the focality at depth in anesthetized mice and monkeys, and using the new focality in awake monkeys, evoked targeted activity at depth in the superior colliculus. The mTI method could be an interesting and potentially useful new tool alongside other forms of non-invasive brain stimulation. Teaser Multipolar Temporal Interference Stimulation can produce a more focal brain stimulation at depth compared to Temporal Interference.
Czech name
—
Czech description
—
Classification
Type
J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database
CEP classification
—
OECD FORD branch
30103 - Neurosciences (including psychophysiology)
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Bioelectronic medicine
ISSN
—
e-ISSN
2332-8886
Volume of the periodical
11
Issue of the periodical within the volume
1
Country of publishing house
GB - UNITED KINGDOM
Number of pages
15
Pages from-to
nestránkováno
UT code for WoS article
001484107600001
EID of the result in the Scopus database
2-s2.0-105001282940