All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Comparison of different enzyme-linked immunosorbent assay methods for avidity determination of antiphospholipid antibodies

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F17%3A10365784" target="_blank" >RIV/00216208:11110/17:10365784 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1002/jcla.22121" target="_blank" >http://dx.doi.org/10.1002/jcla.22121</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1002/jcla.22121" target="_blank" >10.1002/jcla.22121</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Comparison of different enzyme-linked immunosorbent assay methods for avidity determination of antiphospholipid antibodies

  • Original language description

    Background: Avidity of antiphospholipid antibodies may be clinically useful as a valuable additional characteristic. The aim of this study was to compare several ELISA modifications with different chaotropic agents and calculation of avidity indices for the determination of anticardiolipin antibody (aCL) avidity. Methods: We examined 28 serum samples with positive IgG aCL by adapted ELISA using various concentrations of urea and sodium chloride as chaotropic agents and different dilution of sera. We tested these conditions of ELISA-a single diluted serum sample with fixed concentration of a chaotrope and a serially diluted serum in the constant concentration of a chaotropic agent. Results: We demonstrated that ELISA method for avidity determination based on a single dilution of serum in the presence of fixed concentration of chaotrope is convenient for determination of IgG aCL antibody avidity. Concentrations 6 and 8 mol/L of urea or 1 and 2 mol/L of NaCl were suitable for sufficient dissociation of immune complexes during ELISA procedure. Conclusion: This way was in good agreement with more demanding procedures. Both urea and sodium chloride may be used as chaotropic agents. Reference values of avidity indices essential for interpretation of patients&apos; results must be established individually for distinct assay conditions.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10608 - Biochemistry and molecular biology

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Clinical Laboratory Analysis

  • ISSN

    0887-8013

  • e-ISSN

  • Volume of the periodical

    31

  • Issue of the periodical within the volume

    6

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    9

  • Pages from-to

  • UT code for WoS article

    000416049100010

  • EID of the result in the Scopus database

    2-s2.0-85011397544