Boron-doped diamond film and multiple linear regression-based calibration applied to the simultaneous electrochemical determination of paracetamol, phenylephrine hydrochloride, and loratadine in fixed-dose combinations
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F21%3A10426477" target="_blank" >RIV/00216208:11310/21:10426477 - isvavai.cz</a>
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=0SxtLylUeO" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=0SxtLylUeO</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.microc.2020.105831" target="_blank" >10.1016/j.microc.2020.105831</a>
Alternative languages
Result language
angličtina
Original language name
Boron-doped diamond film and multiple linear regression-based calibration applied to the simultaneous electrochemical determination of paracetamol, phenylephrine hydrochloride, and loratadine in fixed-dose combinations
Original language description
In this work, we employed multiple linear regression analyses to satisfactorily determine cold symptoms treatment drugs paracetamol, phenylephrine hydrochloride, and loratadine in pharmaceutical formulations with combined dosage and spiked human urine sample. All the drugs are irreversibly oxidized on the boron-doped diamond electrode (BDDE) in diffusion-controlled oxidation processes with well-separated potentials in acidic media. A square-wave voltammetric (SWV) method was developed for their simultaneous determination in 0.1 mol L-1 H2SO4 and simple and multiple linear regression analyses were compared as calibration methods for SWV data. Precision and selectivity were also studied. The high concentration ratio between paracetamol and the other two drugs being minor components in the formulated dosage forms caused interference in their voltammetric responses. An assay based on multiple linear regression equations considering these multiple effects revealed statistically the same results as those obtained by a comparative HPLC-UV method at a 95% confidence level. We demonstrated that multiple linear regression provided adequate recovery for the determination of PAR, PHE, and LOR in spiked human urine sample. The developed SWV method is a very fast, low-cost, and environmentally friendly alternative to the routine simultaneous analysis of PAR, PHE, and LOR performed by HPLC-UV.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Microchemical Journal
ISSN
0026-265X
e-ISSN
—
Volume of the periodical
162
Issue of the periodical within the volume
March
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
8
Pages from-to
105831
UT code for WoS article
000612265200018
EID of the result in the Scopus database
2-s2.0-85099506004