Hydrophilic interaction liquid chromatography with mass spectrometry for the separation and identification of antisense oligonucleotides impurities and nusinersen metabolites
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F24%3A10473039" target="_blank" >RIV/00216208:11310/24:10473039 - isvavai.cz</a>
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=oY4lu9.c.9" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=oY4lu9.c.9</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chroma.2023.464535" target="_blank" >10.1016/j.chroma.2023.464535</a>
Alternative languages
Result language
angličtina
Original language name
Hydrophilic interaction liquid chromatography with mass spectrometry for the separation and identification of antisense oligonucleotides impurities and nusinersen metabolites
Original language description
With the development of therapeutic oligonucleotides for antisense and gene therapies, the demand for analytical methods also increases. For the analysis of complex samples, for example plasma samples, where the use of mass detection is essential, hydrophilic interaction liquid chromatography is a suitable choice. The aim of the present work was to develop a method for separation and identification of the oligonucleotide impurities and metabolites by hydrophilic interaction liquid chromatography.First of all, the effects of different chromatographic conditions (e.g. pH of the aqueous part of the mobile phase, buffer concentration, column temperature) on the retention and separation of phosphorothioate oligonucleotides standards on the amide stationary phase were investigated. A set of model oligonucleotides containing a fully modified 21mer and its typical impurities (shortmers and oligonucleotides with different number of thiophosphate modifications) was used. The results showed that the concentration of the salt in the mobile phase as well as its pH, are the most influential parameters with regard to peak shape and separation. The knowledge gained was applied to the analysis of an unpurified 18mer oligonucleotides, analogues of the drug nusinersen used for the treatment of spinal muscular atrophy.The successful separation and identification of twenty-six and twenty-eight impurities was performed with the developed HILIC method. The method was applied to analysis of nusinersen metabolites of serum samples of patients treated with Spinraza.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10403 - Physical chemistry
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
1873-3778
Volume of the periodical
1713
Issue of the periodical within the volume
January
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
11
Pages from-to
464535
UT code for WoS article
001126670500001
EID of the result in the Scopus database
2-s2.0-85178160256