All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

UHPLC/MS Coupling: How to Select a Suitable Configuration?

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F12%3A39892155" target="_blank" >RIV/00216275:25310/12:39892155 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216208:11160/12:10124947

  • Result on the web

    <a href="http://dx.doi.org/10.1039/9781849735490" target="_blank" >http://dx.doi.org/10.1039/9781849735490</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1039/9781849735490" target="_blank" >10.1039/9781849735490</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    UHPLC/MS Coupling: How to Select a Suitable Configuration?

  • Original language description

    The UHPLC belongs to the group of fast chromatography techniques, therefore the specific demands of UHPLC/MS coupling on parameters of selected mass analyzer are related to the fact that peaks are narrower compared to the conventional HPLC. The minimum acquisition speed of mass spectrometer in the UHPLC detection should be at least 4-12 Hz, which fits with TOF, Q, IT and LIT mass analyzers, because all of them can reach at least 10 Hz. The fastest mass analyzer is obviously the TOF with common acquisition speeds 40-50 Hz and recently the fastest QqTOF instrument on the market has reached 100 Hz, which allows numerous parallel SRM scans even in ultrafast UHPLC/MS analysis. Additional advantage of modern TOF-based instruments is rather high resolving power (40-60 thousands) and mass accuracy (typically, better than 3 ppm with the external calibration and better than 1 ppm with the internal calibration). Another parameter important for the quantitation is the linear dynamic range, which i

  • Czech name

  • Czech description

Classification

  • Type

    C - Chapter in a specialist book

  • CEP classification

    CB - Analytical chemistry, separation

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2012

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Book/collection name

    UHPLC in Life Science

  • ISBN

    978-1-84973-388-5

  • Number of pages of the result

    25

  • Pages from-to

    186-210

  • Number of pages of the book

    447

  • Publisher name

    Royal Society of Chemistry

  • Place of publication

    Cambridge

  • UT code for WoS chapter