Ventricular electrical heterogeneity in experimental diabetes mellitus: effect of myocardial ischemia
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F16%3A00243340" target="_blank" >RIV/68407700:21460/16:00243340 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Ventricular electrical heterogeneity in experimental diabetes mellitus: effect of myocardial ischemia
Original language description
Aims of the study were to compare the development of electrocardiographic responses of the ischemia-induced heterogeneities of activation and repolarization in the ventricular myocardium of normal and diabetic animals. Methods. Body surface ECGs and unipolar electrograms in 64 epicardial leads were recorded before and during 20 min after the ligation of the left anterior descending artery in diabetic (alloxan model, 4 weeks, n=8) and control (n=8) rabbits. Activation times (ATs), end of repolarization times (RTs) and repolarization durations (activation-recovery intervals, ARIs) were determined in ischemic and periischemic zones. Results. In contrast to the controls, the diabetic rabbits demonstrated the significant prolongation of ATs and shortening of ARIs (P<0.05) during ischemia in the affected region resulting in the development and progressive increase of the ARI and RT gradients across the ischemic zone boundary. The alterations of global and local dispersions of the RTs in diabetics correlated with the Tpeak-Tend interval changes in the limb leads ECGs. Conclusions. In the ischemic conditions, the diabetic animals differed from the controls by the activation delay, significant repolarization duration shortening, and the increase of local repolarization dispersion; the latter could be assessed by the Tpeak-Tend interval measurements in the body surface ECGs.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FA - Cardiovascular diseases including cardio-surgery
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2016
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Physiological Research
ISSN
0862-8408
e-ISSN
—
Volume of the periodical
65
Issue of the periodical within the volume
3
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
9
Pages from-to
437-445
UT code for WoS article
000382115700007
EID of the result in the Scopus database
2-s2.0-84979777157