Selection of suitable sampling tool for reliable soil sampling not only after radiological accident
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00007064%3AK13__%2F19%3AN0000024" target="_blank" >RIV/00007064:K13__/19:N0000024 - isvavai.cz</a>
Výsledek na webu
<a href="https://academic.oup.com/rpd/article-abstract/186/2-3/257/5620703" target="_blank" >https://academic.oup.com/rpd/article-abstract/186/2-3/257/5620703</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncz214" target="_blank" >10.1093/rpd/ncz214</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Selection of suitable sampling tool for reliable soil sampling not only after radiological accident
Popis výsledku v původním jazyce
The objective of this research was to develop a sampling protocol for contaminated soils after a large radiological accident. One of the criteria for good sampling method is reproducibility and accuracy of large number of samples collected in short time. Members of the chemical laboratories of the Fire Rescue Service of the Czech Republic (FRS CR), which are included in Radiation Monitoring Network, tested four tools in different soil types. More than 100 samples were collected. Root auger and square soil sampler seem to be the best for reliable soil sampling. Modifications of the root auger decreased of relative error of sampling to 7.5%. The root auger is recommended as a first-choice sampling tool based on: (1) ease, (2) operator safety, (3) collection of a representative sample (4) applicability to most soil types and (5) enabling collection of depth-discrete samples.
Název v anglickém jazyce
Selection of suitable sampling tool for reliable soil sampling not only after radiological accident
Popis výsledku anglicky
The objective of this research was to develop a sampling protocol for contaminated soils after a large radiological accident. One of the criteria for good sampling method is reproducibility and accuracy of large number of samples collected in short time. Members of the chemical laboratories of the Fire Rescue Service of the Czech Republic (FRS CR), which are included in Radiation Monitoring Network, tested four tools in different soil types. More than 100 samples were collected. Root auger and square soil sampler seem to be the best for reliable soil sampling. Modifications of the root auger decreased of relative error of sampling to 7.5%. The root auger is recommended as a first-choice sampling tool based on: (1) ease, (2) operator safety, (3) collection of a representative sample (4) applicability to most soil types and (5) enabling collection of depth-discrete samples.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10700 - Other natural sciences
Návaznosti výsledku
Projekt
<a href="/cs/project/VI20152020009" target="_blank" >VI20152020009: Cílený aplikovaný výzkum nových moderních technologií, metod a postupů ke zvýšení úrovně schopností HZS ČR - CAVHZS</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Radiation Protection Dosimetry
ISBN
—
ISSN
17423406
e-ISSN
—
Počet stran výsledku
6
Strana od-do
257–262
Název nakladatele
Oxford University Press
Místo vydání
—
Místo konání akce
Mikulov
Datum konání akce
1. 1. 2019
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—