Internal Standards for Quantitative Analysis of Chemical Warfare Agents by the GC/MS Method: Nerve Agents
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00007064%3AK13__%2F21%3AN0000064" target="_blank" >RIV/00007064:K13__/21:N0000064 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Internal Standards for Quantitative Analysis of Chemical Warfare Agents by the GC/MS Method: Nerve Agents
Popis výsledku v původním jazyce
General conditions and requirements for an internal standard useful in the determination of chemical warfare agents (CWAs) by the method of gas chromatography coupled with mass detection (GC/MS) were defined. The determination is based on a GC/MS analysis of a mixture of a CWA with an internal standard, conversion of the TIC chromatogram to a chromatogram extracted at a particular m/z ratio, and calculation of the CWA concentration from the internal standard concentration, response factor, and chromatographic peak areas. Available internal standards were identified, and they were verified for seven organophosphorus nerve-paralysing agents. Corresponding response factors were determined as a ratio of gradients of the linear functions of the peak area and compound concentration. Linearity, repeatability, and accuracy of the measurements were evaluated. The determination can be performed on all GC/MS systems of the Fire Rescue Service of the Czech Republic (FRS), where no CWA standards are available.
Název v anglickém jazyce
Internal Standards for Quantitative Analysis of Chemical Warfare Agents by the GC/MS Method: Nerve Agents
Popis výsledku anglicky
General conditions and requirements for an internal standard useful in the determination of chemical warfare agents (CWAs) by the method of gas chromatography coupled with mass detection (GC/MS) were defined. The determination is based on a GC/MS analysis of a mixture of a CWA with an internal standard, conversion of the TIC chromatogram to a chromatogram extracted at a particular m/z ratio, and calculation of the CWA concentration from the internal standard concentration, response factor, and chromatographic peak areas. Available internal standards were identified, and they were verified for seven organophosphorus nerve-paralysing agents. Corresponding response factors were determined as a ratio of gradients of the linear functions of the peak area and compound concentration. Linearity, repeatability, and accuracy of the measurements were evaluated. The determination can be performed on all GC/MS systems of the Fire Rescue Service of the Czech Republic (FRS), where no CWA standards are available.
Klasifikace
Druh
C - Kapitola v odborné knize
CEP obor
—
OECD FORD obor
10401 - Organic chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/VI20152020009" target="_blank" >VI20152020009: Cílený aplikovaný výzkum nových moderních technologií, metod a postupů ke zvýšení úrovně schopností HZS ČR - CAVHZS</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název knihy nebo sborníku
Prime archives in chemistry
ISBN
978-81-953047-5-2
Počet stran výsledku
29
Strana od-do
—
Počet stran knihy
290
Název nakladatele
Vide Leaf
Místo vydání
—