CFRP Fuselage Panel Behavior Monitoring Using Fibre Optic and Resistance Sensors and Optical Contactless Measurements
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00010669%3A_____%2F16%3AN0000117" target="_blank" >RIV/00010669:_____/16:N0000117 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.scientific.net/AMM.827.51" target="_blank" >https://www.scientific.net/AMM.827.51</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMM.827.51" target="_blank" >10.4028/www.scientific.net/AMM.827.51</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
CFRP Fuselage Panel Behavior Monitoring Using Fibre Optic and Resistance Sensors and Optical Contactless Measurements
Popis výsledku v původním jazyce
The monitoring of stiffened composite panels behavior using resistance strain gauges (SG), fibre optic Bragg grating sensors (FOBG) and contactless optical measurements based on digital image correlation (DIC) principle is discussed in the paper. Both the panel structure and different load cases are specified. Mechanical tests include different load-scenarios like static and fatigue loading in compression of reference and impacted panels. The main reason of failure is buckling. The measurements taken from the sensors captured all changes in the buckling modes of the panel. Moreover, they showed a good correlation between FOBG and SG strain measurements.
Název v anglickém jazyce
CFRP Fuselage Panel Behavior Monitoring Using Fibre Optic and Resistance Sensors and Optical Contactless Measurements
Popis výsledku anglicky
The monitoring of stiffened composite panels behavior using resistance strain gauges (SG), fibre optic Bragg grating sensors (FOBG) and contactless optical measurements based on digital image correlation (DIC) principle is discussed in the paper. Both the panel structure and different load cases are specified. Mechanical tests include different load-scenarios like static and fatigue loading in compression of reference and impacted panels. The main reason of failure is buckling. The measurements taken from the sensors captured all changes in the buckling modes of the panel. Moreover, they showed a good correlation between FOBG and SG strain measurements.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JI - Kompositní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Mechanics and Materials
ISSN
1662-7482
e-ISSN
—
Svazek periodika
827
Číslo periodika v rámci svazku
February 2016
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
6
Strana od-do
51-56
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—