<a href="http://experimentalni-mechanika.cz/konference/2017/file/1355-use-of-fbg-sensors-for-delamination-growth-measurement-under-mode-i-loading.html?tmpl=component" target="_blank" >http://experimentalni-mechanika.cz/konference/2017/file/1355-use-of-fbg-sensors-for-delamination-growth-measurement-under-mode-i-loading.html?tmpl=component</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Use of FBG Sensors for Delamination Growth Measurement under Mode I loading
Popis výsledku v původním jazyce
This paper summarizes the experience gained during the experimental research on sensitivity of optical Fiber Bragg Grating (FBG) sensors. The sensors were embedded inside composite specimens that were subjected to cyclic loading in mode I to achieve delamination growth. Data from the FBG sensors were compared to camera readings to evaluate the ability of the sensors to detect the damage in advance. Average delamination detection advance in loaded state was 6.7 mm and 8.9 mm for the first and the second sensor, respectively. The obtained results will be used to design proposal of the sensor network for an air intake.
Název v anglickém jazyce
Use of FBG Sensors for Delamination Growth Measurement under Mode I loading
Popis výsledku anglicky
This paper summarizes the experience gained during the experimental research on sensitivity of optical Fiber Bragg Grating (FBG) sensors. The sensors were embedded inside composite specimens that were subjected to cyclic loading in mode I to achieve delamination growth. Data from the FBG sensors were compared to camera readings to evaluate the ability of the sensors to detect the damage in advance. Average delamination detection advance in loaded state was 6.7 mm and 8.9 mm for the first and the second sensor, respectively. The obtained results will be used to design proposal of the sensor network for an air intake.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20304 - Aerospace engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/TE02000032" target="_blank" >TE02000032: Výzkumné centrum pokročilých leteckých konstrukcí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
55th Conference on Experimental Stress Analysis 2017
ISBN
978-805533167-6
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
102-107
Název nakladatele
Technical University of Košice
Místo vydání
Košice
Místo konání akce
Nový Smokovec
Datum konání akce
30. 5. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—