Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment results from the EFFICAS I study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F13%3A00058671" target="_blank" >RIV/00023001:_____/13:00058671 - isvavai.cz</a>
Výsledek na webu
<a href="http://circep.ahajournals.org/content/6/2/327" target="_blank" >http://circep.ahajournals.org/content/6/2/327</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1161/CIRCEP.113.000374" target="_blank" >10.1161/CIRCEP.113.000374</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment results from the EFFICAS I study
Popis výsledku v původním jazyce
Background-Pulmonary vein isolation is the most prevalent approach for catheter ablation of paroxysmal atrial fibrillation. Long-term success of the procedure is diminished by arrhythmia recurrences occurring predominantly because of reconnections in previously isolated pulmonary veins. The aim of the EFFICAS I multicenter study was to demonstrate the correlation between contact force (CF) parameters during initial procedure and the incidence of isolation gaps (gap) at 3-month follow-up. Method and Results-A radiofrequency ablation catheter with integrated CF sensor (TactiCath, Endosense, Geneva, Switzerland) was used to perform pulmonary vein isolation in 46 patients with paroxysmal atrial fibrillation. During the ablation procedure, the operator wasblinded to CF information. At follow-up, an interventional diagnostic procedure was performed to assess gap location as correlated to index procedure ablation parameters. At follow-up, 65% (26/40) of patients showed 1 gaps. Ablations with
Název v anglickém jazyce
Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment results from the EFFICAS I study
Popis výsledku anglicky
Background-Pulmonary vein isolation is the most prevalent approach for catheter ablation of paroxysmal atrial fibrillation. Long-term success of the procedure is diminished by arrhythmia recurrences occurring predominantly because of reconnections in previously isolated pulmonary veins. The aim of the EFFICAS I multicenter study was to demonstrate the correlation between contact force (CF) parameters during initial procedure and the incidence of isolation gaps (gap) at 3-month follow-up. Method and Results-A radiofrequency ablation catheter with integrated CF sensor (TactiCath, Endosense, Geneva, Switzerland) was used to perform pulmonary vein isolation in 46 patients with paroxysmal atrial fibrillation. During the ablation procedure, the operator wasblinded to CF information. At follow-up, an interventional diagnostic procedure was performed to assess gap location as correlated to index procedure ablation parameters. At follow-up, 65% (26/40) of patients showed 1 gaps. Ablations with
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Circulation-Arrhythmia and Electrophysiology
ISSN
1941-3149
e-ISSN
—
Svazek periodika
6
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
327-333
Kód UT WoS článku
000320667700021
EID výsledku v databázi Scopus
—