In vitro evaluation of ice-cold saline irrigation during catheter radiofrequeny ablation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F14%3A00059136" target="_blank" >RIV/00023001:_____/14:00059136 - isvavai.cz</a>
Výsledek na webu
<a href="http://onlinelibrary.wiley.com/doi/10.1111/jce.12479/pdf" target="_blank" >http://onlinelibrary.wiley.com/doi/10.1111/jce.12479/pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/jce.12479" target="_blank" >10.1111/jce.12479</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
In vitro evaluation of ice-cold saline irrigation during catheter radiofrequeny ablation
Popis výsledku v původním jazyce
IntroductionIrrigated radiofrequency (RF) catheters allow tissue-electrode interface cooling, decreasing thrombus risk while enabling higher RF power delivery. The impact of irrigation with ice-cold saline (ICS) instead of conventional ambient-temperature saline (ATS) on lesion formation is unknown. Methods and ResultsWe performed 120 RF ablations in vitro on porcine left ventricles, using ICS (<5 degrees C) or ATS (21 degrees C) irrigation. For ICS irrigation, the irrigation circuit was cooled externally to maintain delivery of cooled saline at the catheter's tip. We applied 20g of contact force, and delivered 20 W (irrigation 8 or 17 mL/min) or 30 W (irrigation 17 or 30 mL/min) RF power. Temperatures at tissue-electrode interface and 3-mm depth wereassessed by fluoroptic probes. Lesion dimensions were assessed. ICS irrigation cooled the tissue-electrode interface better than ATS (53.9 9.6 degrees C vs. 63 +/- 11.4 degrees C, P < 0.001). Temperatures at 3-mm depth were similar at 30
Název v anglickém jazyce
In vitro evaluation of ice-cold saline irrigation during catheter radiofrequeny ablation
Popis výsledku anglicky
IntroductionIrrigated radiofrequency (RF) catheters allow tissue-electrode interface cooling, decreasing thrombus risk while enabling higher RF power delivery. The impact of irrigation with ice-cold saline (ICS) instead of conventional ambient-temperature saline (ATS) on lesion formation is unknown. Methods and ResultsWe performed 120 RF ablations in vitro on porcine left ventricles, using ICS (<5 degrees C) or ATS (21 degrees C) irrigation. For ICS irrigation, the irrigation circuit was cooled externally to maintain delivery of cooled saline at the catheter's tip. We applied 20g of contact force, and delivered 20 W (irrigation 8 or 17 mL/min) or 30 W (irrigation 17 or 30 mL/min) RF power. Temperatures at tissue-electrode interface and 3-mm depth wereassessed by fluoroptic probes. Lesion dimensions were assessed. ICS irrigation cooled the tissue-electrode interface better than ATS (53.9 9.6 degrees C vs. 63 +/- 11.4 degrees C, P < 0.001). Temperatures at 3-mm depth were similar at 30
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of cardiovascular electrophysiology
ISSN
1045-3873
e-ISSN
—
Svazek periodika
25
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
1125-1132
Kód UT WoS článku
000343807600015
EID výsledku v databázi Scopus
—