Multiple qualitative and quantitative methods for free light chain analysis are necessary as first line tests for AL amyloidosis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F16%3A00059782" target="_blank" >RIV/00023001:_____/16:00059782 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/16:43911626
Výsledek na webu
<a href="http://www.degruyter.com/view/j/cclm.2016.54.issue-6/cclm-2015-0816/cclm-2015-0816.xml" target="_blank" >http://www.degruyter.com/view/j/cclm.2016.54.issue-6/cclm-2015-0816/cclm-2015-0816.xml</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1515/cclm-2015-0816" target="_blank" >10.1515/cclm-2015-0816</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Multiple qualitative and quantitative methods for free light chain analysis are necessary as first line tests for AL amyloidosis
Popis výsledku v původním jazyce
The objective of this study was to demonstrate the necessity of using different methods for amyloidogenic light chain detection. Serum and urine agarose gel electrophoresis and immunofixation, as well as serum free light chain (FLC) immunoassay measurements, were evaluated in a patient with verified multiple myeloma and consequent AL amyloidosis confirmed by Congo red staining and immunofluorescence techniques. Conventional chemistry tests [serum and urine electrophoresis (SPE and UPE); serum and urine immunofixation (SIFE and UIFE)] were inconclusive. Only quantitative FLC immunoassay (serum free light chain immunoanalysis, SFLC) provided correct diagnostic information. A combination of gel-based SIFE and UIFE with more novel quantitative FLC immunoassays appears necessary when searching for monoclonal immunoglobulin light chain-related diseases.
Název v anglickém jazyce
Multiple qualitative and quantitative methods for free light chain analysis are necessary as first line tests for AL amyloidosis
Popis výsledku anglicky
The objective of this study was to demonstrate the necessity of using different methods for amyloidogenic light chain detection. Serum and urine agarose gel electrophoresis and immunofixation, as well as serum free light chain (FLC) immunoassay measurements, were evaluated in a patient with verified multiple myeloma and consequent AL amyloidosis confirmed by Congo red staining and immunofluorescence techniques. Conventional chemistry tests [serum and urine electrophoresis (SPE and UPE); serum and urine immunofixation (SIFE and UIFE)] were inconclusive. Only quantitative FLC immunoassay (serum free light chain immunoanalysis, SFLC) provided correct diagnostic information. A combination of gel-based SIFE and UIFE with more novel quantitative FLC immunoassays appears necessary when searching for monoclonal immunoglobulin light chain-related diseases.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NV15-27579A" target="_blank" >NV15-27579A: Monoklonální gamapatie u pacientů po transplantaci solidních orgánů. Vztah mezi potransplantační imunosupresí a lymfoproliferativními onemocněními.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Clinical chemistry and laboratory medicine
ISSN
1434-6621
e-ISSN
—
Svazek periodika
54
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
4
Strana od-do
981-984
Kód UT WoS článku
000375209900010
EID výsledku v databázi Scopus
—