Geometric ring annuloplasty as an adjunct to aortic valve repair: clinical investigation of the HAART 300 device
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F16%3A00059842" target="_blank" >RIV/00023001:_____/16:00059842 - isvavai.cz</a>
Výsledek na webu
<a href="http://ejcts.oxfordjournals.org/content/49/3/987.full.pdf+html" target="_blank" >http://ejcts.oxfordjournals.org/content/49/3/987.full.pdf+html</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/ejcts/ezv234" target="_blank" >10.1093/ejcts/ezv234</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Geometric ring annuloplasty as an adjunct to aortic valve repair: clinical investigation of the HAART 300 device
Popis výsledku v původním jazyce
This study assessed the safety and efficacy of an internal geometric annuloplasty ring in a regulatory trial of aortic valve reconstruction (ClinicalTrials.gov Identifier: NCT01400841). Sixty-five patients with predominant moderate-to-severe trileaflet aortic insufficiency (AI) underwent aortic valve repair with an average age of 63 +/- 13 years (mean +/- SD). All had initial implantation of an internal aortic annuloplasty ring to correct annular dilatation and facilitate leaflet reconstruction. Leaflet plication was performed for prolapse in 80% of patients, and more complex leaflet procedures, usually employing autologous pericardium, were required in 22%. Ascending aortic and/or root aneurysms were replaced in 62%. Follow-up was for a maximum of 3 years and a mean of 2 years. No in-hospital operative mortalities, major complications or early or late valve-related events occurred. The annular diameter before repair was 26.5 +/- 2.3 mm, and the average ring diameter used was 21.5 +/- 1.6 mm. The preoperative AI grade (0-4) was 2.9 +/- 0.8 and improved after repair to 0.6 +/- 0.7 (P < 0.0001), as did the NYHA class. The mean valve gradient was 8.6 +/- 4.3 mmHg, and at 3 years, the Kaplan-Meier survival rate was 95%, with no valve-related mortality. Over the 3 years, aortic valve replacement was required in 7 patients (10.8%) for reasons usually related to surgical technique. Most repair failures occurred early, and results stabilized after 6 months. No structural complications of the rings were observed. Geometric ring annuloplasty was a safe and effective adjunct to aortic valve repair. Initial correction of annular dilatation seemed to facilitate overall reconstruction. Because most early repair failures were technical, increasing experience with geometric ring annuloplasty for aortic valve reconstruction has the potential to standardize and improve outcomes.
Název v anglickém jazyce
Geometric ring annuloplasty as an adjunct to aortic valve repair: clinical investigation of the HAART 300 device
Popis výsledku anglicky
This study assessed the safety and efficacy of an internal geometric annuloplasty ring in a regulatory trial of aortic valve reconstruction (ClinicalTrials.gov Identifier: NCT01400841). Sixty-five patients with predominant moderate-to-severe trileaflet aortic insufficiency (AI) underwent aortic valve repair with an average age of 63 +/- 13 years (mean +/- SD). All had initial implantation of an internal aortic annuloplasty ring to correct annular dilatation and facilitate leaflet reconstruction. Leaflet plication was performed for prolapse in 80% of patients, and more complex leaflet procedures, usually employing autologous pericardium, were required in 22%. Ascending aortic and/or root aneurysms were replaced in 62%. Follow-up was for a maximum of 3 years and a mean of 2 years. No in-hospital operative mortalities, major complications or early or late valve-related events occurred. The annular diameter before repair was 26.5 +/- 2.3 mm, and the average ring diameter used was 21.5 +/- 1.6 mm. The preoperative AI grade (0-4) was 2.9 +/- 0.8 and improved after repair to 0.6 +/- 0.7 (P < 0.0001), as did the NYHA class. The mean valve gradient was 8.6 +/- 4.3 mmHg, and at 3 years, the Kaplan-Meier survival rate was 95%, with no valve-related mortality. Over the 3 years, aortic valve replacement was required in 7 patients (10.8%) for reasons usually related to surgical technique. Most repair failures occurred early, and results stabilized after 6 months. No structural complications of the rings were observed. Geometric ring annuloplasty was a safe and effective adjunct to aortic valve repair. Initial correction of annular dilatation seemed to facilitate overall reconstruction. Because most early repair failures were technical, increasing experience with geometric ring annuloplasty for aortic valve reconstruction has the potential to standardize and improve outcomes.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
European journal of cardio-thoracic surgery
ISSN
1010-7940
e-ISSN
—
Svazek periodika
49
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
987-993
Kód UT WoS článku
000372977500047
EID výsledku v databázi Scopus
—