Isovolumic loading of the failing heart by intraventricular placement of a spring expander attenuates cardiac atrophy after heterotopic heart transplantation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F18%3A00077300" target="_blank" >RIV/00023001:_____/18:00077300 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6019382/pdf/bsr-38-bsr20180371.pdf" target="_blank" >https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6019382/pdf/bsr-38-bsr20180371.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1042/BSR20180371" target="_blank" >10.1042/BSR20180371</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Isovolumic loading of the failing heart by intraventricular placement of a spring expander attenuates cardiac atrophy after heterotopic heart transplantation
Popis výsledku v původním jazyce
Cardiac atrophy is the most common complication of prolonged application of the left ventricle (LV) assist device (LVAD) in patients with advanced heart failure (HF). Our aim was to evaluate the course of unloading-induced cardiac atrophy in rats with failing hearts, and to examine if increased isovolumic loading obtained by intraventricular implantation of an especially designed spring expander would attenuate this process. Heterotopic abdominal heart transplantation (HTx) was used as a rat model of heart unloading. HF was induced by volume overload achieved by creation of the aorto-caval fistula (ACF). The degree of cardiac atrophy was assessed as the weight ratio of the heterotopically transplanted heart (HW) to the control heart. Isovolumic loading was increased by intraventricular implantation of a stainless steel three-branch spring expander. The course of cardiac atrophy was evaluated on days 7, 14, 21, and 28 after HTx. Seven days unloading by HTx in failing hearts sufficed to substantially decrease the HW (-59 +/- 3%), the decrease progressed when measured on days 14, 21, and 28 after HTx. Implantation of the spring expander significantly reduced the decreases in whole HW at all the time points (-39 +/- 3 compared with -59 +/- 3, -52 +/- 2 compared with -69 +/- 3, -51 +/- 2 compared with -71 +/- 2, and -44 +/- 2 compared with -71 +/- 3%, respectively; P<0.05 in each case). We conclude that the enhanced isovolumic heart loading obtained by implantation of the spring expander attenuates the development of unloading-induced cardiac atrophy in the failing rat heart.
Název v anglickém jazyce
Isovolumic loading of the failing heart by intraventricular placement of a spring expander attenuates cardiac atrophy after heterotopic heart transplantation
Popis výsledku anglicky
Cardiac atrophy is the most common complication of prolonged application of the left ventricle (LV) assist device (LVAD) in patients with advanced heart failure (HF). Our aim was to evaluate the course of unloading-induced cardiac atrophy in rats with failing hearts, and to examine if increased isovolumic loading obtained by intraventricular implantation of an especially designed spring expander would attenuate this process. Heterotopic abdominal heart transplantation (HTx) was used as a rat model of heart unloading. HF was induced by volume overload achieved by creation of the aorto-caval fistula (ACF). The degree of cardiac atrophy was assessed as the weight ratio of the heterotopically transplanted heart (HW) to the control heart. Isovolumic loading was increased by intraventricular implantation of a stainless steel three-branch spring expander. The course of cardiac atrophy was evaluated on days 7, 14, 21, and 28 after HTx. Seven days unloading by HTx in failing hearts sufficed to substantially decrease the HW (-59 +/- 3%), the decrease progressed when measured on days 14, 21, and 28 after HTx. Implantation of the spring expander significantly reduced the decreases in whole HW at all the time points (-39 +/- 3 compared with -59 +/- 3, -52 +/- 2 compared with -69 +/- 3, -51 +/- 2 compared with -71 +/- 2, and -44 +/- 2 compared with -71 +/- 3%, respectively; P<0.05 in each case). We conclude that the enhanced isovolumic heart loading obtained by implantation of the spring expander attenuates the development of unloading-induced cardiac atrophy in the failing rat heart.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
<a href="/cs/project/NV16-27420A" target="_blank" >NV16-27420A: Přístupy k zabránění rozvoje srdeční atrofie po implantaci levostranné srdeční podpory: studie na potkaním modelu heterotopické transplantace srdce</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Bioscience reports
ISSN
1573-4935
e-ISSN
—
Svazek periodika
38
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
17
Strana od-do
"art. no. BSR20180371"
Kód UT WoS článku
000463152000001