Intraventricular placement of a spring expander does not attenuate cardiac atrophy of the healthy heart induced by unloading via heterotopic heart transplantation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F19%3A00078215" target="_blank" >RIV/00023001:_____/19:00078215 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11130/19:10398478
Výsledek na webu
<a href="http://www.biomed.cas.cz/physiolres/pdf/68/68_567.pdf" target="_blank" >http://www.biomed.cas.cz/physiolres/pdf/68/68_567.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.33549/physiolres.933936" target="_blank" >10.33549/physiolres.933936</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Intraventricular placement of a spring expander does not attenuate cardiac atrophy of the healthy heart induced by unloading via heterotopic heart transplantation
Popis výsledku v původním jazyce
An important complication of the prolonged left ventricle assist device support in patients with heart failure is unloading-induced cardiac atrophy which proved resistant to various treatments. Heterotopic heart transplantation (HTx) is the usual experimental model to study this process. We showed previously that implantation of the newly designed intraventricular spring expander can attenuate the atrophy when examined after HTx in the failing heart (derived from animals with established heart failure). The present study aimed to examine if enhanced isovolumic loading achieved by implantation of the expander would attenuate cardiac post-HTx atrophy also in the healthy heart. Cardiac atrophy was assessed as the ratio of the transplanted-to-native heart weight (HW) and its degree was determined on days 7, 14, 21 and 28 after HTx. The transplantation resulted in 32±3, 46±2, 48±3 and 46±3 % HW loss when measured at the four time points; implantation of the expander had no significant effect on these decreases. We conclude that enhanced isovolumic loading achieved by intraventricular implantation of the expander does not attenuate the development of cardiac atrophy after HTx in the healthy heart. This indicates that such an approach does not represent a useful therapeutic measure to attenuate the development of unloading-induced cardiac atrophy.
Název v anglickém jazyce
Intraventricular placement of a spring expander does not attenuate cardiac atrophy of the healthy heart induced by unloading via heterotopic heart transplantation
Popis výsledku anglicky
An important complication of the prolonged left ventricle assist device support in patients with heart failure is unloading-induced cardiac atrophy which proved resistant to various treatments. Heterotopic heart transplantation (HTx) is the usual experimental model to study this process. We showed previously that implantation of the newly designed intraventricular spring expander can attenuate the atrophy when examined after HTx in the failing heart (derived from animals with established heart failure). The present study aimed to examine if enhanced isovolumic loading achieved by implantation of the expander would attenuate cardiac post-HTx atrophy also in the healthy heart. Cardiac atrophy was assessed as the ratio of the transplanted-to-native heart weight (HW) and its degree was determined on days 7, 14, 21 and 28 after HTx. The transplantation resulted in 32±3, 46±2, 48±3 and 46±3 % HW loss when measured at the four time points; implantation of the expander had no significant effect on these decreases. We conclude that enhanced isovolumic loading achieved by intraventricular implantation of the expander does not attenuate the development of cardiac atrophy after HTx in the healthy heart. This indicates that such an approach does not represent a useful therapeutic measure to attenuate the development of unloading-induced cardiac atrophy.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
<a href="/cs/project/NV16-27420A" target="_blank" >NV16-27420A: Přístupy k zabránění rozvoje srdeční atrofie po implantaci levostranné srdeční podpory: studie na potkaním modelu heterotopické transplantace srdce</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physiological research
ISSN
0862-8408
e-ISSN
—
Svazek periodika
68
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
14
Strana od-do
567-580
Kód UT WoS článku
000483374200005
EID výsledku v databázi Scopus
2-s2.0-85071710327